Instructions / Assembly
These Control Boxes remotely controls 3 wire single phase Submersible Deep Well Pump Motors
and are to be used specifically with motors manufactured by Faradyne. See the Electrical Ratings
section for list of motors to be used with respective control boxes.
Model HP Voltage Hz Amps Ph Capacitor Relay
EFCB5-1 1/2 115V 60 8.8 1 250-300Mfd, 115V 115V
EFCB5 1/2 230V 60 5.3 1 59-71Mfd, 220V 230V
EFCB7 3/4 230V 60 6.6 1 86-103Mfd, 220V 230V
EFCB10 1 230V 60 8.1 1 105-126Mfd, 220V 230V
Wiring connection
1. All electrical wiring must be in accordance with local code and only qualified electricians should
make the installations.
2. All wires should be checked for shorts to ground with an ohmmeter or megger after the connections
are made. This is IMPORTANT, as one grounded wire can cause failure of the pump, control panel
or personal injury.
For parts or assistance, call ECO-FLO Customer Service at 1-877 326-3561
3
Start Capacitor
BK
Main(B)
Y
Start(R) L2 L1
YL
RD
OR
1/2 - 1 HP
Relay
1
25
Use only copper conductors
Line InMotor Leads
Applications