Install the unit with a minimum clearance of 30.5 cm (12 in) from the floor and 61 cm (24 in) from the
ceiling.
Do not install directly on or beside wallpaper, furniture, mirrors, fittings, laminate or any surfaces that
are not fire resistant as the heat will impact the appearance and physical properties of those materials.
Position the unit at a minimum of 61cm (24in) away horizontally from curtains, and other flammable
materials. Take into account possible air drafts coming from adjacent doors and windows to
determine the applicable safe distance from those openings to install your unit.
Always securely install the protective glass guard provided with the unit according to the Installation
section of this manual.
CAUTION
Risks of burns. Do not operate the unit without the protective glass guard completely attached.
WARNING
DO NOT PACK REQUIRED AIR SPACES WITH INSULATION OR OTHER MATERIALS.
INSTALLATION INSTRUCTIONS
Recommended minimum clearances around
a Wall Mounted Model
Overhead: 60cm (24in)
Sides: 30cm (12in)
From floor: 30cm (12in) (If built-into wall)
Front: Accessible at all times
1. Free Standing Installation
a. With the help of a second person,
place the unit sideways or upside
down to facilitate the installation
of the free standing feet A. Line
up the holes on the free standing
feet A with the holes A on the
bottom of the unit.
b. Lock the feet into position by using
washers, the socket cap recessed hex
screws ‘E’ and the Allen key included
with the unit.
(FREE STANDING INSTALLATION ONLY)
Do not use free-standing feet A for built-in installation.