SDS

Safety Data Sheet
Boost PLUS Diesel Engine Fuel Additive
Version: 2.0, p. 4 of 10
SECTION 6: Accidental release measures
6.1 Personal precautions, protective equipment and emergency procedures
Use personal protective equipment. Avoid breathing vapors, mist or gas. Ensure adequate ventilation. Remove all
sources of ignition. Evacuate personnel to safe areas. Beware of vapors accumulating to form explosive
concentrations. Vapors can accumulate in low areas. For personal protection see section 8.
6.2 Environmental precautions
Avoid release to the environment. Do not let product enter drains.
6.3 Methods and materials for containment and cleaning up
Eliminate all sources of ignition. Soak up with inert absorbent material and dispose of as hazardous waste. Keep
in suitable, closed containers for disposal.
Reference to other sections
For disposal see section 13.
SECTION 7: Handling and storage
7.1 Precautions for safe handling
Avoid contact with skin and eyes. Avoid inhalation of vapor or mist. Wash hands with soap and water after handling.
Container explosion may occur under fire conditions. Use explosion-proof equipment. Use only non-sparking tools.
Keep away from sources of ignition. No smoking. Take measures to prevent the buildup of electrostatic charge.
For precautions see section 2.
7.2 Conditions for safe storage, including any incompatibilities
Storage: Keep container tightly closed in a dry, cool and well-ventilated place. Containers which are opened must
be carefully resealed and kept upright to prevent leakage.
Incompatible Products: Oxidizers, strong acids.
Incompatible Materials: Source of ignitions. Heat sources.
Storage: Store away from heat. Store in a cool area. Store in a dry area. Store in a well-ventilated place.
Special rules on packaging: Keep only in original container. Meet the legal requirements.
Specific end use(s)
Apart from the uses mentioned in section 1 no other specific uses are stipulated.
SECTION 8: Exposure controls/personal protection
8.1 Control parameters
1. Cumene (CAS: 98-82-8)
PEL (Inhalation): 50 ppm (OSHA)
OSHA Annotated Table Z-1, www.osha.gov
PEL (Inhalation): 245 mg/m3 (OSHA)
OSHA Annotated Table Z-1, www.osha.gov