Operation Manual
ENGLISH
Bedienungsanleitung / Instruction manual CONTROVENTO
28
8.3 Warehousing
• Keep the machine packed in a dry place.
• Do not stack the units on top of each other.
• Do not place other heavy items on the packaging.
9 DISPOSAL
WEEE Reg.-Nr.: DE69510123
This product complies with EU Directive 2002/96/EC and is registered according to WEEE (Waste Electrical and
Electronic Equipment).
10 CE CONFORMITY
Conformity
The product complies with the following EU Directives:
Machine: 2006/42/EC
Low Voltage: 2006/95/EC
EMC: 2004/108/EC
PED: 97/23/EC
EN-Directives: EN 292-1, EN 292-2, EN 60335-1, EN 60335-2-15 or EN 60335-2-75,
EN 55014, EN 61000-3, EN 61000-4, ENV 50141, EN 55104
11 TROUBLESHOOTING
Problem Possible Cause Troubleshooting
The grind is not fine enough.
Use a finer grind.
Tamp the ground coffee more firmly.
Reduce the brewing pressure.
The coffee is too old. Use fresh coffee
Little or no crema on the top of the
coffee
There is too much chlorine in the
water.
Use a chlorine filter.
The amount of ground coffee is not
enough.
Use the right coffee amount: approx.
7 – 9 g of coffee for each cup.
Little or no crema on top of the
coffee
The shower screen is dirty. Clean the brew group.
The grind is too fine.
Set a coarser grind.
Tamp the ground coffee with less
force. Increase the brewing pressure.
Sparse coffee dispensing, only drop
by drop
There is too much ground coffee.
Use approx. 7 – 9 g of coffee for
every cup.
The grind is not fine enough. Set a finer grind.
The coffee is old. Use fresh coffee.
The amount of ground coffee is not
enough.
Use approx. 7 – 9 g of coffee for
each cup.
Weak “body”
The shower screen is dirty. Clean the shower screen.
Problem Possible Cause Troubleshooting
The beans are improper. Use another type of coffee bean.
Foam instead of crema
The setting of the coffee grinder is
not suited for the coffee beans in
use.
Adjust the coffee grinder (When
changing the coffee beans, changing
the grind may also be necessary.)
The machine is switched on, but the
machine does not work.
PID-display is turned off: There is
not enough water in the fresh water
tank.
Refill water.