Service manual
Options
74
DCB, DCFCB and DCFCTB Models
Options
Model 2001TRB
This option uses a transformer/rectifier for primary system power with battery
back-up and allows the siren to operate from a 208, 220 or 240 VAC power source
without the use of the batteries. During a power failure, an automatic switch to
battery operation occurs to maintain the siren’s normal operation. Specify the AC line
voltage when ordering.
The 2001TRB has a 115 VAC secondary tap to provide power to the siren control
cabinet.
2001TRB Mounting Location
Keep wire lengths to a minimum. Mount the transformer assembly as close as
possible to the Control Unit/Battery Box.
2001TRB Specifications
OPERATING
Voltage
208/220/240 VAC, 60 Hz single phase
Current
30 Amps approx. (nom.) (50 Amp service recommended)
Fusing
35 Amps, slow blow
Weight
150 pounds (68.2 kg.)
Dimensions
23.5‖ H (596mm) x 10.25‖ W (260mm) x 11.75‖ D (298mm)
2001TRB Wiring
Electrocution or severe personal injury can occur when making electrical
connections, drilling holes, or lifting equipment. Therefore, only experienced
electricians should install this product in accordance with national and local electrical
codes.
Note: Federal recommends using wire no smaller than 3 AWG between the
transformer and the Control Unit/Battery Box. To perform the wiring, proceed
as follows (refer to Figure 17 Schematic Diagram 2001TRB and Figure 18
Transformer Rectifier Wiring to Control Unit).