Service manual

Installation
59
DCB, DCFCB and DCFCTB Models
HTR4 (Battery Warmers) section on page 81 and Figure 21 HTR2 and HTR4
Wiring Diagram).
2. There are several wires entering the battery cabinet: a red 4 AWG, a black 4
AWG, and a multiple conductor cable. The red and black 4 AWG wires provide
48 VDC operating power to the siren. The multiple conductor cable provides the
charge current for the batteries. Several white wires with lugs on each end are
also packaged with the batteries. These white wires are used to connect the
batteries in series.
3. Connect the wires to the batteries per Figure 13 Battery Positioning and Wiring
and securely fasten all connections.
4. Apply user supplied silicon grease, or other oxide inhibiting compound to the
battery terminals.
Figure 13 Battery Positioning and Wiring