Service manual
27
Functional Description
DCB, DCFCB and DCFCTB Models
Proximity Switch Rotation Sensor Input: JP5-7 is used to connect a proximity
switch to detect siren rotation. You may leave this input unconnected if a
non-rotating siren is used or if JP10-3 is used to detect rotation. During a normal
siren activation (when the siren is rotating), the external rotation sensor, which is
usually an open collector proximity device mounted in the siren to detect gear
movement, provides active low pulses. Once this input receives more than 11 low
pulses during a siren activation, this input will latch active until a reset command
is received.
Digital Input for Current Sensor
JP5-5 is used to detect the main siren motor operating current during siren activation.
This input is pulled low when the external current sensor detects proper running
current during a siren activation. If this input is pulled low for 1/4 second, the input is
latched active until another activation command is received or a Reset command is
sent.
Digital Input for Intrusion Sensor
JP5-3 is used to detect an intrusion into the control cabinet. With the control cabinet
closed, the intrusion switch is in a normally closed position. If the intrusion condition
changes state for more than one second, an auto-report is sent.
Digital Input for Pressure Sensor (not used with 2001-130 sirens)
JP5-1 is used to detect blower pressure on Thunderbolt sirens during siren activation.
This sensor input latches when operating current is detected (input is pulled low) and
resets when a RESET command is received.
Relay Outputs
JP21
Pin
Out
1
Relay 1, Common
2
Relay 1, N.O.
3
Relay 2, Common
4
Relay 2, N.O.
5
Relay 3, Common
6
Relay 3, N.O. or N.C., depending on jumper JU1,
(N.C is standard)
7
Relay 4, Common
8
Relay 4, N.O. or N.C., depending on jumper JU2,
(N.O. is standard)
There are four (4) relay outputs, which are controlled by the microprocessor. The
relays provide isolation and are spike protected to prevent voltage spikes from
affecting the unit. As the relay coil is energized, the outputs close and the associated
LED lights. The DCFCB and DCFCTB come standard with two DPST relays. Relay