Service manual

17
Functional Description
DCB, DCFCB and DCFCTB Models
JP9
LEDs on with Intrusion
1
Short to pin 2, to disable LEDs when Intrusion switch is closed.
JP10
Remote Activation and Sensor Inputs (#1 at left edge of
connector)
1
Spare Sensor Input #2, dry Contact closure < 1 K.
2
ISO Ground.
3
Spare Sensor Input #1, dry Contact closure < 1 K.
4
ISO Ground.
5
Remote Activation Input #4, Activates Functions under code 4,
dry Contact closure < 1 K.
6
ISO Ground.
7
Remote Activation Input #3, Activates Functions under code 3,
dry Contact closure < 1 K.
8
ISO Ground.
9
Remote Activation Input #2, Activates Functions under code 2,
dry Contact closure < 1 K.
10
ISO Ground.
11
Remote Activation Input #1, Activates Functions under code 1,
dry Contact closure < 1 K.
12
ISO Ground.
JP11
Emulation and Options Emulation
1
TCK
2
GND
3
TDO
4
VCC (+5V)
5
TMS
6
RESET NOT
7
VCC (+5V)
8
N.C.
9
TDI
10
GND
Options
Jumper pins 1 and 2 for Solar mode
For 2001 DC Solar mode
AC
(Power)
AC and External Power or 50VDC (AC power or 48V
battery/Charger) Latching
Battery
>12.3v (DC-DC) AND >41.6 (48V battery)
Pressure
Motor fuse (low = pass)