Service manual

8
Specifications
DCB, DCFCB and DCFCTB Models
Specifications
Specifications for the Controllers
Input Power Requirements
Input Power Requirements
AC Voltage
120 +/- 10%, 50-60 Hz
Current draw
4.0 Amps at 120 VAC (nominal)
7 Amps with HTR2 or HTR4 option
AC Power and Battery Warmer Options
-240B: Step-down Battery
Charger Transformer
(Required when only
240VAC is available)
Input Voltage
230 VAC single phase
Output Voltage
115 VAC (nominal)
Power Rating
0.75 KVA
2001TRB: AC Primary
Operation
Input Voltage
208/220/240 VAC single phase
Input Current
30 Amps (approx.)
Output Voltage
46 VDC/115 VAC
(50 Amp service recommended, to be fused with
35 Amp Slo-Blow)
Output Current
120 Amps DC/10 Amps AC
Dimensions (HxWxD)
23" x 11" x 10"
584mm x 279mm x 254mm
Weight
150 lb. (68.2 kg.)
HTR2 and HTR4: Battery
Warmers
Input Voltage
125 VAC single phase
Power Rating
80 Watts each
System Operating Power from the 4 Battery System
System Operating Power from the 4 Battery System
Output Voltage
48 VDC (nominal)
Operating Current during an activation
115 Amps (nominal)
Continuous Full Output Signaling Time
20 minutes (minimum)
Stand-by time on Reserve Battery Capacity
that provides a full 3-minute siren activation.
5 days minimum