Types of Battery Backups:
As a CCI customer you will have one of the following Battery Backups:
1. Allied Telesis DUPS-1232GI (AT-iMG008)
2. APC ES 750
3. APC PowerShield CP24
4. APC PowerShield CP27U13 U12
5. APC PowerShield CP24D12
Maintenance
Please see below for instructions and information on the Battery Backups listed above.
1. Allied Telesis DUPS-1232GI (AT-iMG008)
Indicator Signals:
The ALARM SILENCE button is used to silence the battery backup unit’s alarm. The BATTERY
EMERGENCY USE button provides power for an emergency call in the event of a lengthy
power outage.
✓
X
TYPE SYMBOL CONDITION ALARM ACTION
System Status
System ON and normal,
idle or discharging
ON GREEN
Battery Power
Battery Charging
Battery Discharging
<45% capacity remaining
OFF
ON
FLASH GREEN
Replace Battery Battery failed self test ON RED
Auxiliary Power
Aux source connected
to unit
ON GREEN
TYPE CONDITION BUZZER
Input Power Fail Loss of input power None
Replace Battery Battery failed self test
Beep once every
15 minutes
Low Battery <45% capacity remaining None
ON Battery Battery being discharged None
Battery Missing
No battery installed or
battery disconnected
None
✓
System Status
Battery Power
Replace Battery
Auxiliary Power
X
!
Alarm Silence
Battery
Emergency
Use