Instruction Manual

16
MIMO88 DIGITAL MATRIX
TYPE PARAM1 PARAM2 PARAM3 PARAM4 DESCRIPTION
DATA
PRESET <Preset Number> Shows the current PRESET
ILEVEL <Input Channel> <Level> Shows the current LEVEL of an Input Channel
OLEVEL <Output Channel> <Level> Shows the current LEVEL of an Output
Channel
XLEVEL <Input Channel> <Output Channel> <Level> Shows the current LEVEL for a Matrix point
IMUTE <Input Channel> YES/NO Shows the current MUTE status of an Input
Channel
OMUTE <Output Channel> YES/NO Shows the current MUTE status of an Output
Channel
XMUTE <Input Channel> <Output Channel> YES/NO Shows the current MUTE status for a Matrix
Point
IVU <Input Channel> <Pre Vumeter Level> <Post Vumeter Level> Shows the VU-meter value of an Input Channel
OVU <Output Channel> <Pre Vumeter Level> <Post Vumeter Level> Shows the VU-meter value of an Output
Channel
GPI <Input> <GPI Value> Shows the current value of a General Purpose
Input
GPO <Output> <GPO Value) Shows the current value of a General Purpose
Output
INFO_NAME “<Device Name>” Shows the Device Name
INFO_MODEL <Device Model> Shows the Device Model
INFO_VERSION <Firmware Version> Shows the Firmware Version
INFO_MAC <Device MAC address> Shows the Device MAC address
ERROR
<Error ID> “<Error Description>” Informs about an error