NPA STEREO AMPLIFIER SERIES
TYPE PARAM1 PARAM2 PARAM3 PARAM4 DESCRIPTION
SET
POWER ON/OFF Sets the Device Power status
PRESET <Preset Number> Sets the current PRESET
OLEVEL <Output Channel> <Level> Sets the current LEVEL of an Output
Channel
OMUTE <Output Channel> YES/NO Sets the current MUTE status of an
Output Channel
SUBSCRIBE
ALL Subscribes to all VU-meters
OVU <Output Channel> Subscribes to an Output Channel VU-
meter
UNSUBSCRIBE
ALL Unsubscribe to all VU-meters
OVU <Output Channel> Unsubscribe to an Output Channel VU-
meter
DATA
POWER ON/OFF Shows the Device Power status
PRESET <Preset Number> Shows the current PRESET
OLEVEL <Output Channel> <Level> Shows the current LEVEL of an Output
Channel
OMUTE <Output Channel> YES/NO Shows the current MUTE status of an
Output Channel
OVU <Output Channel> <Pre Vumeter Level> <Post Vumeter Level> Shows the VU-meter value of an Output
Channel
ALARM_PROTECT <Output Channel> ON/OFF Shows the Protect alarm status of an
Output Channel
ALARM_THERMAL <Output Channel> ON/OFF Shows the Thermal alarm status of an
Output Channel
ALARM_LOAD <Output Channel> ON/OFF Shows the Load alarm status of an Output
Channel
ALARM_VOLTAGE ON/OFF Shows the Voltage alarm status of the
Device
INFO_NAME “<Device Name>” Shows the Device Name
INFO_MODEL <Device Model> Shows the Device Model
INFO_VERSION <Firmware Version> Shows the Firmware Version
INFO_MAC <Device MAC address> Shows the Device MAC address
ERROR