Instruction Manual

12
NPA STEREO AMPLIFIER SERIES
TYPE PARAM1 PARAM2 PARAM3 PARAM4 DESCRIPTION
SYSTEM
CONNECT [PINGPONG] Saves the client IP address for responses and then
dumps current device status (with DATA messages)
DISCONNECT Cancel subscriptions and terminates
communication
SUBSCRIPTION_RATE <Rate> Alive message from device
PING Alive message from device
PONG Alice ACK message from client
GET
ALL Dumps current device status (with DATA
messages)
POWER Gets the Device Power status
PRESET Gets the current PRESET
OLEVEL <Output Channel> Gets the current LEVEL of an Output Channel
OMUTE <Output Channel> Gets the current MUTE status of an Output Channel
OVU <Output Channel> Gets the VU-meter value of an Output Channel
ALARM_PROTECT <Output Channel> Gets the Protect alarm status of an Output Channel
ALARM_THERMAL <Output Channel> Gets the Thermal alarm status of an Output
Channel
ALARM_LOAD <Output Channel> Gets the Load alarm status of an Output Channel
ALARM_VOLTAGE Gets the Voltage alarm status of the Device
INFO_NAME Gets the Device Name
INFO_MODEL Gets the Device Model
INFO_VERSION Gets the Firmware Version
INFO_MAC Gets the Device MAC address