3. INSTALLATION and CONNECTION
3.1. Installation
Installing a MPAGE16 unit consists of the following steps:
1. Cable setup:
a. MPAGE16 control and supply bus (4 cores: CHAN H, CHAN L, +DC, GND)
must be connected to one of the MIMO88 control bus ports (REMOTE 1 or
2), in “
daisy-chain
” (bus devices chained in series), and the last of them
must have a 120 ohms terminal resistance between HIGH and LOW pins.
The maximum length for the control bus cable is 800 m.
b. When using two consoles connected to a single MIMO88, both can be
connected at the same port or different ones, as required in the setup. See
picture with the two options.
+
DC
GND
CAN H
MIC +
CAN L
-
1
6
R
+
DC
GND
CAN H
MIC +
CAN L
MIC
-
1
6
R
1
6
REMOTE 1
IN1 IN8
-
-
-
MIMO 88
MIMO 88
MPAGE16
(1)
+
+
DC
GND
CAN H
MIC +
CAN L
MIC
-
1
6
R
1
6
REMOTE 2
IN1 IN8
-
-
MIMO 88
+
1
6
REMOTE 1
IN1 IN8
-
-
+
MIMO 88
IN1 IN8
-
+
MIC
+
DC
GND
CAN H
MIC +
CAN L
-
MIC
1
6
MPAGE16
(2)
MPAGE16
(1)
MPAGE16
(2)