User Manual
CA‐NETProtocol
page3/29
And6inthecaseoftheCA200z:
o LINE1
o LINE2
o LINE2
o LINE4
o MICRO1
o MICRO2
<Preset Number> is a numerical value that identifies one available Preset stored in the
device’smemory.Itcanbewithinthe[1..5]range.
<Volume Level> are numerical values in the [0…64] range that define values in a scale
equivalentto[‐inf...Maximum_Volume]in1.25dBsteps.
<Tone Level> are numerical values in the [‐10…10] range that define values in a scale
equivalentto[‐10,‐8,‐6,‐4,‐2,0,2,4,6,8,10]dB.
Ifthenumericalvalueisnotinthislist,
theunitwillreplywithanerrormessage.
<IncrementValue> are numerical values inthe [0…64]range that define a valuein a scale
equivalent to [Increment Value]x(1.25) dB, used to increase or decrease the current
absolutevalueofalevel.
<ThresholdLevel>theallowednumericalvaluesinthisfieldarejust3[20,25,30].Itdefines
a value in a scale equivalent to [20, 25, 30] dB below the nominal level value for a given
audio input. If the numerical value is not in this list, the unit will reply with an error
message.
<DepthLevel> theallowednumericalvaluesinthisfieldarejust4[20,30,60,80].Itdefines
avalue in a scale equivalentto[20, 30, 60,80]dB.If thenumericalvalueisnot in this list,
theunitwillreplywithanerrormessage.
<AttackTimeValue>theallowednumericalvaluesinthisfieldarejust4[50,100,200,300].
Itdefinesa valuein a scaleequivalentto [50,100, 200, 300] milliseconds.If thenumerical
valueisnotinthislist,theunitwillreplywithan
errormessage.
<ReleaseTimeValue>theallowednumericalvaluesinthisfieldarejust5[300,500,1000,
2000, 3000]. It defines a value in a scale equivalent to [300, 500, 1000, 2000, 3000]
milliseconds. If the numerical value is not in this list, the unit will reply with an
error
message.
<RemoteSelectValue>aretext strings (without blankspaces)thatidentifythefunctionof
theanalogue(0–10VDC)remotecontrolselectorconnectedtoaphysical“REMOTE”port
inthedevice.
InthecaseoftheCA40,therearejusttwopossiblestringvaluesforthisparameter:
o INPUTS
o PRESETS
AndthreeinthecaseoftheCA200z: