TYPE PARAM1 PARAM2 PARAM3 PARAM4 DESCRIPCIÓN
SET AUTOLOAD_PRESET1 ON/OFF SetsthecurrentAUTOLOAD_PRESET1atStartupfunction
PRESET_NUMBER <Preset=P1:P10>
<Preset=T1:T6>
Sets(loads)thecurrentPRESETnumber
LOAD_PRESET <Preset=P1:P10>
<Preset=T1:T6>
Sets(loads)thecurrentPRESETnumber(samefunctionas
PRESET_NUMBER)
SAVE_PRESET <Preset=P1:P10> “<Name>” SavesthecurrentconfigurationintoacertainPRESETposition(from
P1toP10)andwithacertainLABEL,orname(betweenquotation
markstoallowforblankcharactersinthelabel)
REMOTE_MODE <Remote=R1:R4> <RemoteMode> Setstheworkingmodeforacertai nREMOTEport(fromR1toR4).
Validworkingmodesare:DISABLED,IN_VOL,ZONE_VOL,IN_SEL,
IN_SEL_IN_LEVEL,IN_SEL_ZONE_VOL,PRESET,PRESET_ZONE_VOL
REMOTE_INPUTS <Remote=R1:R4> <Inputs=I1:I5> Setsthelistofinputsaffectedbythewo rkingmodeofacertain
REMOTEport(fromR1toR4).InputsparametercanincludeI1toI5,
separatedbycommacharactersandnoblankspace(example:
I1,I2,I3)
REMOTE_ZONES <Remote=R1:R4> <Zones=ZA:ZD> Setsthelistofoutputsaffectedbytheworkingmodeofacertain
REMOTEport(fromR1toR4).ZonesparametercanincludeZAto
ZD,separatedbycommacharactersandnoblankspace(example:
ZA,ZC,ZD)
DISPLAY_MODE <DisplayMode> SetsthecurrentLCDDISPLAYMODE(NORMALorDIMMEDorOFF)
LCD_CONTRAST <Contrast=0:100> SetsthecurrentLCDDISPLAYCONTRASTlevel
EXT_MUTE_ZONES <Zones=ZA:ZD> Setsthelistofoutputstobemutedbyanexternalcontactclosure,
connectedtotheMUTEport.ZonesparametercanincludeZAto
ZD,separatedbycommacharactersandnoblankspace(example:
ZA,ZC,ZD)
IN_LABEL <Input=I1:I5> “<Label>” Sets the current LABEL (name) for the specified INPUT (between
quotationmarkstoallowforblankcharactersinthelabel)
IN_STEREO <Input=I4:I5> ON/OFFSetsthecurrentSTEREOlinkstatus(ONorOFF)forINPUTs4and5
IN_MUTE <Input=I1:I5> ON/OFFSetsthecurrentMUTEstatus(ONorOFF)forthespecifiedINPUT
IN_VOL <Input=I1:I5> <Volume=0:99 > SetsthecurrentVOLUMEforthespecifiedINPUT(generalinput