GATE_ACTIVE <Input=I4:I5> GetsthecurrentNOISEGATEstatus(ONorOFF)forthespecified
INPUT
GATE_THRESHOLD <Input=I4:I5> GetsthecurrentNOISEGATETHRESHOLDLEVEL(dBx10)forthe
specifiedINPUT
GATE_DEPTH <Input=I4:I5> GetsthecurrentNOISEGATEDEPTH(attenuationwhengateisclosed,
dBx10)forthespecifiedINPUT
GATE_ATTACK <Input=I4:I5> GetsthecurrentNOISEGATEATTACKTIME(millisecondsx10)forthe
specifiedINPUT
GATE_HOLD <Input=I4:I5> GetsthecurrentNOISEGATEHOLDTIME(millisecondsx10)forthe
specifiedINPUT
GATE_RELEASE <Input=I4:I5> GetsthecurrentNOISEGATERELEASETIME(millisecondsx10)forthe
specifiedINPUT
TALKOVER_ACTIVE <Input=I4:I5> GetsthecurrentTALKOVERstatus(ONorOFF)forthespecifiedINPUT
TALKOVER_MODE <Input=I4:I5> GetstheTALKOVERfunctionworkingmode(PAGERorDUCKER)forthe
specifiedINPUT
TALKOVER_PRIORITY <Input=I4:I5> GetsthecurrentTALKOVERPRIORITYle vel(LOWorHIGH)forthe
specifiedINPUT
TALKOVER_ZONES <Input=I4:I5> GetsthecurrentTALKOVERassignmenttooutputs(ZONES)forthe
specifiedINPUT
TALKOVER_THRESHOLD <Input=I4:I5> GetsthecurrentTALKOVERTHRESHOLDLEVEL(dBx10)forthe
specifiedINPUT
TALKOVER_DEPTH <Input=I4:I5> GetsthecurrentTALKOVERDEPTH(attenuation,dBx10)forthe
specifiedINPUT
TALKOVER_ATTACK <Input=I4:I5> GetsthecurrentTALKO VERATTACKTIME(millisecondsx10)forthe
specifiedINPUT
TALKOVER_HOLD <Input=I4:I5> GetsthecurrentTALKOVERHOLDTIME(millisecondsx10)forthe
specifiedINPUT
TALKOVER_RELEASE <Input=I4:I5> GetsthecurrentTALKOVERRELEASETIME(millisecondsx10)forthe
specifiedINPUT
CHIME_MELODY <Input=I4:I5> GetsthecurrentCHIMEMELODYselectedfortheTALKOVERfunction
inPAGERmode
CHIME_VOL <Input=I4:I5> GetsthecurrentCHIMEMELODYVOLUME(dBx10)adjustedforthe
TALKOVERfunctioninPAGERmode