AMAZING GOOP
®
II
MAX™
ULTIMATE REPAIR GLUE - REAL WORLD TOUGH. REAL WORLD USE.
AMAZING GOOP
®
II MAX™ | Rev 03 – Effective: 14May01 / Approved: 35TMorgan Page | 2
CHEMICALS THAT HAVE LITTLE OR NO EFFECT ON AMAZING GOOP® II MAX™
Acetic acid (5% and 10%)
Ammonium hydroxide (3.4%)
Ammonium nitrate (50%)
Antifreeze
Beer (3.2% alcohol by volume)
Boric acid (3.1%)
Distilled water
Hydraulic oil
Lactic acid (3.8%)
Milk (fresh, tested at 40 °F)
Motor oil (30w)
Nitric acid (10% and 20%)
Oxalic acid (3.1%)
Phosphoric acid (30% and 60% as P
2
O
5
)
Potassium hydroxide (3.4%)
Sodium carbonates (2.7%)
Sodium chloride (10%)
Sulfuric acid (3% and 10%)
Wine (20% alcohol by volume)
AMAZING GOOP®
II
MAX™ exhibits excellent resistance to water,
dilute acids and dilute bases. Thin films of AMAZING GOOP®
II
MAX™ were immersed in various chemicals for two weeks and
exhibited weight gains of less than 2% and tensile strength loss of
less than 10%. These chemicals are listed on the left. All
percentages are given by weight unless otherwise noted.
SOLVENTS THAT DISSOLVE AMAZING GOOP® II MAX™
Chevron solvent 1100
Chlorothane NU
Cyclohexane
Gasoline
Methylene chloride
Perchloroethylene
Propyl acetate
Toluene
1, 1, 1-Trichloroethane
These are common solvents that dissolve AMAZING GOOP® II
MAX™ when hardened samples were immersed. The dissolution
with these solvents was not instantaneous and therefore does not
preclude usage in all cases. Applications were an occasional splash
or brief exposure is expected may be acceptable. Test a small area
before full use.
DIRECTIONS and APPLICATION NOTES
Read directions and test small area before use.
Step 1
Surface should be clean, dry and free of dirt. For best results, lightly roughen surface
before use.
Step 2
Puncture seal in neck of tube using pointer cap. Product can be used between 50 and
90 °F / 10 and 32 °C.
Step 3
For non-porous surfaces, apply a thin coat to each surface. Wait approximately
2 minutes before mating surfaces.
Step 4
For maximum-strength bond, allow 24-72 hours for cure time.
Step 5
For future easy cap removal, apply a thin coat of petroleum jelly to the threads of the
tube before replacing the cap.
Step 6
Clean uncured adhesive with acetone or citrus-based solvents.
For technical assistance, call 800.767.4667.
May damage finished surfaces. Avoid such contact until completely dry. Not recommended for use
on polystyrene, polyethylene, polypropylene, Styrofoam™ or paper products, and any items that
come into contact with food, drinking water or animals. Do not dry clean.