Specifications
Installation B-FOCuS O-4F2P
3-8 ECI Telecom Ltd. Proprietary
Connecting Ethernet Lines
1. Locate the premises’ Ethernet LAN cable.
2. If the cable is not terminated, follow local practices to attach an RJ-45
connector. Table shows Ethernet RJ-45 connector wiring information.
3. Plug the Ethernet cable into the B-FOCuS O-4F2P RJ-45 Ethernet port.
4. Repeat step 2-3 as needed to connect additional Ethernet cables.
Table 8: Ethernet RJ-45 connector wiring pattern
Pin Color Signal Pin Color Signal
1 Orange/White Tx + 5 Blue/White Unused
2 Orange Tx — 6 Green Rx —
3 Green/White Rx + 7 Brown/White Unused
4 Blue Unused 8 Brown Unused
Verify the Installation
Check LED states to verify ONT O-4F2P status.
Services are not available until the ONT is ranged and provisioned in the PON
network. The B-FOCuS O-4F2P is activated and configured through the E-OPS
Element Manager. Refer to the E-OPS Hi-Care User Guide for details.
Verifying B-FOCuS O-4F2P Status
Once the B-FOCuS O-4F2P installation is complete, follow the procedure
below for verifying B-FOCuS O-4F2P status. The figures below show the
typical status LED display after the B-FOCuS O-4F2P boot sequence is
complete.