EFS-CA1200 INSTALLATION MANUAL
Thank you for purchasing the EchoMaster EFS-CA1200 With EFS-CA1200, your mobile assets are in good hands. This durable IP66 rated asset tracker will add GPS tracking and asset manager to fleet equipment, passenger vehicles, off-road vehicles and more. Please ensure you read and understand all aspects of the manual before installing or using the EchoMaster products.
EFS-CA1200 INSTALLATION GUIDE Chassis Ground Connect the BLACK (-) Input wire to a solid chassis ground uninhibited by paint or rust, you mustn’t use any floating grounds from the vehicle’s electrical system. Always connect the ground wire directly to the assets chassis and secure the connection with a factory bolt or aftermarket selftapping screw..
STEP 3: TESTING THE EFS-CA1200 After installation move the asset outside and leave it running for five minutes allowing time for the GPS receiver to receive a good signal from the GPS satellites. 2. Click the settings gear in the upper right corner CONFIRMING THE LED LIGHTS Upon initial power-up of the EFS-CA1200, the LEDs on the top of the device will start flashing, Identifying the Mode status of the device.
7. In the list of devices, find the device you just installed. Click the “>” symbol on the right side to open that device, and assign it to the vehicle you just added. 4. Select Add Vehicle from the upper right corner 8. Once the device has been assigned, click back to the map view to confirm that the location and status is correct for the vehicle that was just set up. 5. Fill out the vehicle’s information and save 6. Select Devices from the left menu 8 email - support@aampglobal.
Issue Cause Unit Does Not Power-up Power is not connected to the unit. With a Digital Voltmeter, measure the voltage at the input to the unit. A positive voltage should be measured on the + terminal of the unit when measuring between the + terminal and the - terminal or chassis ground. This voltage should also measure 12 VDC. Correct the wiring to assure the correct polarity and the correct voltage level. Check fuse. Bad Ground connection.