Blower User Manual
26
st o r a g e
   WARNING 
During operation the mufer or catalytic mufer and surrounding cover become hot. Always keep exhaust area clear 
of ammable debris during transportation or when storing, otherwise serious property damage or personal injury 
may result.
Long Term Storage (Over 30 Days)
Do not store your unit for a prolonged period of time (30 days or longer) without performing protective storage mainte-
nance which includes the following:
  1.  Store unit in a dry, dust free place, out of the reach of children.
   DANGER
Do not store in enclosure where fuel fumes may accumulate or reach an open ame or spark.
  2.  Place the stop switch in the "STOP" position.
  3.  Remove accumulation of grease, oil, dirt and debris 
from exterior of unit.
  4.  Perform all periodic lubrication and services that are 
required.
  5.  Tighten all screws and nuts.
  6.  Drain the fuel tank completely and pull the recoil 
starter handle several times to remove fuel from the 
carburetor.
  7.  Remove the spark plug and pour 7cc (1/4 oz.) of 
fresh, clean ECHO 2-stroke engine oil into the cyl-
inder through the spark plug hole.
    A.  Place a clean cloth over the spark plug hole.
    B.  Pull the recoil starter handle 2-3 times to   
  distribute the oil inside the engine.
    C.  Observe the piston location through the spark 
  plug hole. Pull the recoil handle slowly until the 
  piston reaches the top of its travel and leave it 
  there.
  8.  Install the spark plug (do not connect ignition cable).
  9.  Remove blower pipe assembly from unit.