Power Blower
oPerator's Manual
sTarTIng Cold engIne 
•  Recoil starter: Use short pulls - only 1/2-2/3 of rope length for start-
ing. Do not allow the rope to snap back in. Always hold the unit 
rmly.
•  Rotate throttle handle downward to a comfortable operating position.
 1.  Throttle Position Lever
    Move throttle position lever (A) to START/IDLE DETENT posi-
tion(
).
 2.  Choke
    Move choke (B) to "Cold Start" (
) position.
 3.  Purge Bulb
   Pump purge bulb (C) until fuel is visible and ows freely in the 
clear fuel tank return line.
 4.  Recoil Starter
    Pull recoil starter handle (D) until engine res, or maximum 5 
pulls.
 5.  Choke
    Move choke (B) to run (
) position and if necessary, restart 
engine.
NOTE 
If engine does not start after 5 pulls, repeat instructions 2-5.
NOTE 
Allow engine to warm up before use.
D
B
A
C