sTarTIng Cold engIne
Recoil starter: Use short pulls - only 1/2-2/3 of rope length for start-
ing. Do not allow the rope to snap back in. Always hold the unit
rmly.
Rotate throttle handle downward to a comfortable operating position.
1. Throttle Position Lever
Move throttle position lever (A) to START/IDLE DETENT posi-
tion(
).
2. Choke
Move choke (B) to "Cold Start" (
) position.
3. Purge Bulb
Pump purge bulb (C) until fuel is visible and ows freely in the
clear fuel tank return line.
4. Recoil Starter
Pull recoil starter handle (D) until engine res, or maximum 5
pulls.
5. Choke
Move choke (B) to run (
) position and if necessary, restart
engine.
NOTE
If engine does not start after 5 pulls, repeat instructions 2-5.
NOTE
Allow engine to warm up before use.