Use and Care Manual

26
Storage
PREPARATION FOR STORAGE
The following procedures should be followed prior to storage of your
generator for periods of 6 months or longer.
1. Drain fuel from fuel tank carefully by disconnecting the fuel line.
Gasoline left in the fuel tank will eventually deteriorate making
󰀩
2. Remove the drain screw of the carburetor.
3. Change engine oil.
4. Check for loose bolts and screws, tighten them if necessary.
5. Clean generator thoroughly with clean cloth. NEVER USE WATER
TO CLEAN GENERATOR.
6. Pull recoil starter handle until resistance is felt, leaving handle in
that position.
7. Store generator in a well ventilated, low humidity area.
Generator Specications
STORAGE
Engine Model R210
Start Manual
Rated Frequency 60Hz
Rated Voltage 120V
Rated Power 2.8KW
DC Output 12V, 8.3A
Fuel Tank Capacity 15L
Full Load Continuum Running Time 7h
50% Load Continuum Running Time 10h
Noise (7m) 72dB

2 x GFCI Duplex with water
proof cover, 1 x 120V- 30A
Twist lock-3 prongs with
water proof cover, Low oil
indicator

CSA/EPA/CARB
LOW THD
N/A
Wheels & Kits
Yes