OPERATION DPAS-2600SB
26 X7508230800
©11/21 ECHO Incorporated
Starting The Unit
The attachment will operate when the battery is installed, the
power indicator LED is lit, and the trigger switch and trigger
switch lockout are engaged. Make sure the product is properly
positioned to prevent loss of control and possible serious
injury.
1. Keep movable parts of the
attachment away from
objects that could become
entangled or thrown, and
surfaces that could cause
loss of control.
2. Push power button (A) once
to turn on power to unit.
Power indicator LED (B)
illuminates when power to
unit is turned on.
3. Hold down trigger switch
lockout (C) and depress trigger switch (D) to increase RPM to operating
speed.
Note: To increase operating speed, press + (E). To decrease
operating speed, press - (F). Press and hold + button for one
second to maintain consistent speed. Press + again to
cancel.
When power to unit is turned on:
• After 90 seconds of inactivity, unit will power itself off.
• If the LED remains lit, operation is normal.
• If the LED flashes once per second, the battery needs to be charged.
• If the LED flashes four times per second, there is a fault within the
product. Turn power off to unit. Remove battery. Clear debris from around
line head. Install battery. Turn power on to unit. If flashing continues, have
your authorized servicing dealer repair the product.