Use and Care Manual

Table Of Contents
MAINTENANCE DCS-2500T
56 X7508220201
© 4/22 ECHO Incorporated
Automatic Oiler
1. The discharge volume
of the automatic oiler is
adjusted to 7 mL/min
approximately at 7000 r/
min, prior to shipment
from factory.
2. To increase the delivery
volume, turn the
adjusting screw (F)
counterclockwise.
3. When adjusting screw touches stops, it has reached maximum
discharge volume. (13 mL/min at 7000 r/min).
4. Do not turn the adjusting screw beyond the maximum or minimum limit
of volume adjustment.
Cooling System
1. Check periodically.
2. Remove debris blocking
air inlet (G) and outlet
(H).
Clean the unit with the air filter attached to it in order to prevent trash
from entering inside.
F
C
G
H