Power Blower Operator's Manual MODEL PB-200 WARNING DANGER Read rules for safe operation and all instructions carefully. ECHO provides this Operator’s Manual, which must be read and understood for proper and safe operation.
INTRODUCTION Welcome to the ECHO family. This ECHO product was designed and manufactured to provide long life and on-the-jobdependability. Read and understand this manual. You will find it easy to use and full of helpful operating tips and SAFETY messages. THE OPERATOR’S MANUAL Read and understand this manual before operation. Keep it in a safe place for future reference.
POWER BLOWER OPERATOR'S MANUAL SAFETY MANUAL SAFETY SYMBOLS AND IMPORTANT INFORMATION Throughout this manual and on the product itself, you will find safety alerts and helpful, informational messages preceded by symbols or key words. The following is an explanation of those symbols and key words and what they mean to you. This symbol accompanied by the words WARNING and DANGER calls attention to an act or condition that can lead to serious personal injury to operator and bystanders.
Physical Condition Your judgment and physical dexterity may not be good: • if you are tired or sick, • if you are taking medication, • if you have taken alcohol or drugs. Operate unit only if you are physically and mentally well. Eye Protection Wear eye protection that meets ANSI Z87.1 or CE requirements whenever you operate the unit. Hand Protection Wear no-slip, heavy-duty work gloves to improve your grip on the blower handle. Gloves also reduce the transmission of machine vibration to your hands.
POWER BLOWER OPERATOR'S MANUAL Repetitive Stress Injuries It is believed that overusing the muscles and tendons of the fingers, hands, arms, and shoulders may cause soreness, swelling, numbness, weakness, and extreme pain in those areas. Certain repetitive hand activities may put you at a high risk for developing a Repetitive Stress Injury (RSI). An extreme RSI condition is Carpal Tunnel Syndrome (CTS), which could occur when your wrist swells and squeezes a vital nerve that runs through the area.
EQUIPMENT CHECK WARNING DANGER Use only ECHO approved attachments. Serious injury may result from the use of a non-approved attachment combination. ECHO, INC. will not be responsible for the failure of cutting devices, attachments or accessories which have not been tested and approved by ECHO. Read and comply with all safety instructions listed in this manual and safety manual. • Check unit for loose/missing nuts, bolts and screws. Tighten and/or replace as needed.
POWER BLOWER OPERATOR'S MANUAL DESCRIPTION Locate these safety decals on your unit. Make sure the decals are legible and that you understand and follow the instructions on them. If a decal cannot be read, a new one can be ordered from your ECHO dealer. See PARTS ORDERING instructions for specific information.
1. 2. 3. 4. 5. 6. 7. 8. 9. STOP SWITCH - "SLIDE SWITCH" mounted on top of handle. Push forward to start and run. Slide back to stop. THROTTLE TRIGGER - Spring loaded to return to idle when released. During acceleration, press trigger gradually for best operating technique. SPARK PLUG - Provides spark to ignite fuel mixture. SPARK ARRESTOR - CATALYTIC MUFFLER / MUFFLER -The muffler or catalytic muffler controls exhaust noise and emission.
POWER BLOWER OPERATOR'S MANUAL ASSEMBLY WARNING DANGER Never perform maintenance or assembly procedures with engine running or serious personal injury may result. BLOWER APPLICATION Install Blower Pipes 1. Align grooves in straight pipe with pegs on blower housing and slide pipe onto housing. 2. Turn straight pipe clockwise to lock into place. 3. Align grooves in fan head nozzle with pegs on straight pipe and slide fan head nozzle onto straight pipe. 4.
Two Stroke Oil - A two-stroke engine oil meeting ISO-L-EGD (ISO/CD 13738) and J.A.S.O. FC Standards must be used. Echo brand premium Power Blend TM Universal 2-Stroke Oil meets these standards. Engine problems due to inadequate lubrication caused by failure to use an ISO-L-EGD and J.A.S.O. FC certified oil, such as Echo premium Power Blend TM, will void the two-stroke engine warranty.
POWER BLOWER OPERATOR'S MANUAL STARTING COLD ENGINE • Provide all operators of this equipment with the Operator's Manual and instructions for safe operation. • Before starting the unit, equip yourself and any other person working within the 15 m (50 ft.) Safety Zone with the required Protective Equipment and clothing. 1. Stop Switch Move stop switch button (A) away from the STOP position. 2. Throttle Position Move throttle position lever (B) midway between idle and full throttle positions. 3.
STARTING WARM ENGINE The starting procedure is the same as Cold Start except DO NOT close the choke. 1. Stop Switch Move stop switch button (A) away from the STOP position. 2. Throttle Position Move throttle position lever (B) midway between idle and full throttle positions. 3. Recoil Starter Place the unit on a flat clear area. Firmly grasp throttle grip with left hand and rapidly pull recoil starter handle/rope (E) until engine fires.
POWER BLOWER OPERATOR'S MANUAL OPERATING BLOWER WARNING DANGER Always wear safety glasses, hearing protection and a face filter mask or serious personal injury may result. . Do not point the blower pipe in the direction of people or pets. Read the Safety Section carefully. IMPORTANT To avoid engine damage due to over-revving, do not block blower pipe. 1. Use only during appropriate hours. 2. Allow the engine to warm up at a fast idle for a few minutes. 3.
MAINTENANCE Your ECHO blower is designed to provide many hours of trouble free service. Regular scheduled maintenance will help your blower achieve that goal. If you are unsure or are not equipped with the necessary tools, you may want to take your unit to an ECHO Service Dealer for maintenance. To help you decide whether you want to DO-IT-YOURSELF or have the ECHO Dealer do it, each maintenance task has been graded. If task is not listed, see your ECHO Dealer for repairs.
POWER BLOWER OPERATOR'S MANUAL AIR FILTER Level 1. Tools required: 25-50 mm (1-2 in.) Cleaning brush. Parts required: 90008 REPOWERTM Air and Filter Kit NOTE Clean daily. 1. ]). This prevents dirt from Close choke (Cold Start Position [ entering the carburetor throat when the air filter is removed. Brush accumulated dirt from air cleaner area. 2. Remove air filter cover. Brush dirt from inside cover. 3. Remove air filter and lightly brush debris from filter.
SPARK PLUG Level 2. Tools required: 3/4 in. Spark Plug deep socket, Feeler gauge Parts Required: REPOWERTM Tune-Up Kit P/N 90074C IMPORTANT Use only NGK BPM-8Y spark plug (BPMR-8Y in Canada) otherwise severe engine damage may occur. 1. Remove spark plug and check for fouling, worn and rounded center electrode. 2. Clean the plug or replace with a new one. DO NOT sand blast to clean. Remaining sand will damage engine. 3. Adjust spark plug gap by bending outer electrode. 4.
POWER BLOWER OPERATOR'S MANUAL 17 Cleaning Cylinder Fins 1. Remove spark plug lead and spark plug. 2. Remove two upper 3 mm hex screws at recoil starter. 3. Remove engine cover (five screws), pull cover away from engine. Loosely install spark plug to prevent dirt from entering cylinder. Clean cylinder fins to allow cooling air to pass freely. 4. Remove spark plug and loosely reassemble engine cover with five cross head and two hex head screws. 5. Tighten all screws securely. 6.
Cylinder Exhaust Port Level 3. IMPORTANT The cylinder exhaust port must be inspected and cleaned of excess carbon every 3 months or 90 hours of operation in order to maintain this engine within the emissions durability period. ECHO strongly recommends that you return your unit to your ECHO dealer for this important maintenance service. CARBURETOR ADJUSTMENT Engine Break-In New engines must be operated a minimum duration of two tanks of fuel break-in before carburetor adjustments can be made.
POWER BLOWER OPERATOR'S MANUAL 19 TROUBLESHOOTING TROUBLESHOOTING CHART Problem Engine cranks starts hard/ doesn't start C h eck Status Fuel at carburetor No fuel at carburetor Fuel at cylinder C au se Remedy Fuel strainer clogged Fuel line clogged Carburetor Clean or replace Clean or replace See your Echo dealer No fuel at cylinder Carburetor See your Echo dealer Muffler wet with fuel Fuel Mixture too rich Open choke Clean/replace air filter Adjust carburetor See your Echo dealer Spark a
STORAGE WARNING DANGER During operation the muffler or catalytic muffler and surrounding cover becomes hot. Always keep exhaust area clear of flammable debris during transportation or when storing, otherwise serious property damage or personal injury may result. Long Term Storage (Over 30 Days) Do not store your unit for a prolonged period of time (30 days or longer) without performing protective storage maintenance which includes the following: 1.
POWER BLOWER OPERATOR'S MANUAL 21 SPECIFICATIONS MODEL ----------------------------------------------------- PB-200 Hand Held Length ------------------------------------------------------- 330 mm (13.0 in.) (w/o pipes) Width -------------------------------------------------------- 215 mm (8.5 in.) Height ------------------------------------------------------- 340 mm (13.4 in.) Weight (dry) ------------------------------------------------ 3.8 kg (8.38 lb.
NOTES
POWER BLOWER OPERATOR'S MANUAL NOTES 23
SERVICING INFORMATION PARTS/SERIAL NUMBER Genuine ECHO Parts and ECHO REPOWER™ Parts and Assemblies for your ECHO products are available only from an Authorized ECHO Dealer. When you do need to buy parts always have the Model Number, Type and Serial Number of the unit with you. You can find these numbers on the engine housing. For future reference, write them in the space provided below. Model No. _____________ Type _________SN.