Owner`s manual
27
using compatible clocks. One device will operate as the source of the master
clock, with each successive device using that clock to sync.
Digital Mode Switch
To the right of the Input clocks is a dropdown menu labeled “
Dig Mode
.”
This menu allows you to select which digital inputs/outputs Mona will use
at any given time. The options are
S/PDIF RCA
,
S/PDIF optical
, and
ADAT optical
. Mona can only use one digital mode at a time.
When one of the two S/PDIF modes is selected, the “
Show ADAT
Controls
” checkbox will be grayed out. You can only access the ADAT
controls when the ADAT mode is currently selected.
Note:
Sample rates above 48kHz will not be available while ADAT mode
is selected. This is because the ADAT optical standard does not support
sample rates higher than 48kHz.