Owner`s manual
28
Now a little more complicated set-up: You have two Layla24s connected.
Simply set Layla24 #1 to
Internal
for its input clock. Now connect the first
Layla24 to the second one via a BNC cable running from Word Clock Out
on Layla24 #1 to Word Clock In on Layla24 #2. Now select
Word
for
Layla24 #2’s input sync. The second Layla24 will slave to the first one and
your Layla24s will now operate in unison.
No matter how many devices you are synchronizing, the concept is
essentially the same. You are merely “daisy-chaining” devices together
using compatible clocks. One device will operate as the source of the master
clock, with each successive device using that clock to sync.
Digital Mode Switch
To the right of the Input clocks is a dropdown menu labeled “
Dig Mode
.”
This menu allows you to select which digital inputs/outputs Layla24 will
use at any given time. The options are
S/PDIF RCA
,
S/PDIF optical
, and
ADAT optical
. Layla24 can only use one digital mode at a time.
When one of the two S/PDIF modes is selected, the “
Show ADAT
Controls
” checkbox will be grayed out. You can only access the ADAT
controls when the ADAT mode is currently selected.
Note:
Sample rates above 48kHz will not be available while ADAT mode
is selected. This is because the ADAT optical standard does not support
sample rates higher than 48kHz.