User`s guide
PCLTA-21 PCI Interface User’s Guide
21
• Loaded Image Size: the size, in bytes, of the currently-loaded PCLTA-21
system image. This may be zero if the PCLTA-21 card is in the initial boot
state.
• Interrupt Count: the number of interrupts the driver has processed for this
device. This value is set to zero when the device is physically reset.
Diagnostic Commands
The diagnostic commands are invoked by clicking one of the buttons displayed in
figure 3.6. If a diagnostic command results in the “Image file not found” error
message, close the Diagnostics dialog by clicking the OK button, then click the
Apply button in the PCLTA-21 control panel application. This re-initializes the
card and allows use of the diagnostic commands.
Figure 3.6 Diagnostics Dialog Box Commands
Test
The Test button retrieves status and error counts from the PCLTA-21 card. The
results of this message will be displayed in the format shown in figure 3.7.
Figure 3.7 Example Network Diagnostics Status Response