System information

Table Of Contents
i.LON SmartServer 2.0 Programmer’s Reference
7-18
<UCPTdescription />
</DataPoint>
<DataPoint xsi:type="UFPTalarmNotifier_DpRef" dpType="Output">
<UCPTname>Net/LON/iLON App/VirtFb/temp_f</UCPTname>
<UCPTnickName>Net/LON/iLON App/VirtFb/temp_f</UCPTnickName>
</DataPoint>
<DataPoint xsi:type="UFPTalarmNotifier_DpRef" dpType="Output">
<UCPTname>Net/LON/iLON App/Digital Output 1/nviClaValue_1</UCPTname>
<UCPTnickName>Net/LON/iLON App/Digital Output 1/nviClaValue_1</UCPTnickName>
</DataPoint>
<DataPoint xsi:type="UFPTalarmNotifier_DpRef" dpType="Output">
<UCPTname>Net/LON/iLON App/Digital Output 2/nviClaValue_2</UCPTname>
<UCPTnickName>Net/LON/iLON App/Digital Output 2/nviClaValue_2</UCPTnickName>
</DataPoint>
<SCPTdelayTime>0</SCPTdelayTime>
<UCPTsumLogSize>50</UCPTsumLogSize>
<UCPThistLogSize>100</UCPThistLogSize>
<UCPTlogFormat xsi:type="string" LonFormat="UCPTlogFormat">LF_TEXT</UCPTlogFormat>
<UCPTsumLogFileName>Net/LON/iLON App/Alarm Notifier[0]_Summary.csv</UCPTsumLogFileName>
<UCPThistLogFileName>Net/LON/iLON App/Alarm Notifier[0]_History.csv</UCPThistLogFileName>
<UCPTemailAggregTime>0</UCPTemailAggregTime>
<ActiveAlarm>
<UCPTindex>5</UCPTindex>
<UCPTlevel>240</UCPTlevel>
<UCPTalarmText>Alarm</UCPTalarmText>
<UCPTalarmCondition LonFormat="UCPTalarmCondition">AL_ALM_CONDITION</UCPTalarmCondition>
</ActiveAlarm>
<PassiveAlarm>
<UCPTindex>0</UCPTindex>
<UCPTlevel>255</UCPTlevel>
<UCPTalarmText>Online</UCPTalarmText>
<UCPTalarmCondition LonFormat="UCPTalarmCondition">AL_NO_CONDITION</UCPTalarmCondition>
</PassiveAlarm>
<AlarmDest>
<UCPTindex>0</UCPTindex>
<UCPTenablePath xsi:type="string" />
<ActiveDest xsi:type="UFPTalarmNotifier_CfgAlarmDestination">
<UCPTdataPointPath xsi:type="string">DataPoint[@dpType="Output" and
UCPTnickName="Net/LON/iLON App/Digital Output 1/nviClaValue_1"]
</UCPTdataPointPath>
<UCPTpointValue>ON</UCPTpointValue>
<UCPTminLevel>255</UCPTminLevel>
<UCPTmaxLevel>0</UCPTmaxLevel>
<UCPTnackDelay>0</UCPTnackDelay>
</ActiveDest>
<PassiveDest xsi:type="UFPTalarmNotifier_CfgAlarmDestination">
<UCPTdataPointPath xsi:type="string">
DataPoint[@dpType="Output" and UCPTnickName="Net/LON/iLON App/Digital Output
2/nviClaValue_2"]
</UCPTdataPointPath>
<UCPTpointValue>OFF</UCPTpointValue>
<UCPTminLevel>255</UCPTminLevel>
<UCPTmaxLevel>0</UCPTmaxLevel>
<UCPTnackDelay>0</UCPTnackDelay>
</PassiveDest>
</AlarmDest>
</Item>
</iLonItem>
</Set>
7.3.4
Using the Read Function on an Alarm Notifier
Each time an Alarm Notifier causes an alarm notification, it will record an entry for the notification
into its log file. You can use the Read function to retrieve the log entries that an Alarm Notifier has
recorded. You must reference the Alarm Notifier to return log entries for by its <UCPTname>in the
input you supply to the function.
The alarm log files are stored in the /root/AlarmLog directory of the SmartServer. These files are
named histlogX, where X represents the index number assigned to the Alarm Notifier when it was