User's Manual
36 Meter Operation
Status Name Description Event ID Descriptor
Log Dimension
Changed
The dimensions or semantics of the
meter’s interface have changed.
88 0000 = Initial meter load
0002 = Interface compatibility setting changed during
commissioning.
0003 = Interface compatibility changed via a table
write.
0xxx = Procedure invoked causing interface
compatibility change, where xxx is the number of the
procedure invoking the change
Unread Load
Profile Entries
Exist
Unread entries exist in the load profile
log.
94
MEP Status
Changed
Status has changed for a MEP device. 96 0 = Device 0 is commissioned and assigned to
position 1, 2, 3, or 4
1 = Device 0 commission failed, no available position
2 = Device 0 commission failed, lost communication
4 = Device 0 removed logically from meter
8192 = Device 1 is commissioned
8193 = Device 1 commissioned failed, no available
position
8194 = Device 1 commission failed, lost
communication
8196 = Device 1 removed logically from meter
16384 = Device 2 is commissioned
16385 = Device 2 commission failed, no available
position
16386 = Device 2 commission failed, lost
communication
16388 = Device 2 removed logically from meter
24576 = Device 3 is commissioned
24577 = Device 3 commission failed, no available
position
24578 = Device 3 commission failed, lost
communication
24580 = Device 3 removed logically from meter
32768 = Device 4 is commissioned
32769 = Device 4 commission failed, no available
position
32770 = Device 4 commission failed, lost
communication
32772 = Device 4 removed logically from meter
40960 = Device 5 is commissioned
40961 = Device 5 commission failed, no available
position
40962 = Device 5 commission failed, lost
communication
40964 = Device 5 removed logically from meter
40965 = Device 5 registered ( MEP devices only)