User's Manual

34 Meter Operation
Status Name Description Event ID Descriptor
Season Change A TOU season change occurred. 24 0 = Season 1
1 = Season 2
2 = Season 3
3 = Season 4
Special Schedule
Activation
A day deemed as a TOU holiday. 26 0 = Special schedule A
1 = Special schedule B
Tier Switch
Change
The meter switched from one tariff to
another per day table settings or via
procedure (forced tariff change).
27 0 = Tariff 1
1 = Tariff 2
2 = Tariff 3
3 = Tariff 4
Pending Table
Activation
The TOU pending table was activated. 28 4119 = Internal system use
4150 = Preset TOU schedule changeover
Pending Table
Clear
The TOU pending table was cleared. 29 4119 = Internal system use
4150 = Preset TOU schedule changeover was
cancelled
Test Mode
Started
The meter has entered test mode. 30
Test Mode
Stopped
The meter has exited test mode. 31
Meter
Reprogrammed
New firmware operating code was written
to the meter.
36 New firmware version number (Echelon-internal
formatting)