User's Manual

Table Of Contents
Street Light Bridge Integrator’s Guide 45
If error simulation mode is active, error simulation mode is restarted
with the new timeout value, regardless of how much time has already
passed or how much time would be left in the previous simulation.
If error simulation mode is not active, the value is stored but has no other
immediate effect.
Note that a value of zero (0) is not valid for the nciErrTimeout configuration
network variable; the Street Light Bridge application rounds a zero value up to 1
(one) to ensure that error simulation mode can eventually end.
Error Codes
The Segment Controller displays the last error code on the Web page for the
Street Light Bridge module. You can also use network management tools to send
a query status message to the Street Light Bridge module to retrieve the error
log. See the
Neuron Tools Errors Guide
(078-0402-01B) for a listing of Neuron
firmware error codes. The Street Light Bridge firmware can also post the errors
listed in
Table 1.
Table 1. Street Light Bridge Firmware Error Codes
Error Description
0x40 Logged when a download fails because the image has a bad CRC, fails to
decompress, or is improperly formed in some way.
0x41 Logged when a download fails because an image is incompatible with the
target. This error includes image incompatibility (for example, not a
Street Light Bridge image), hardware incompatibility, bootrom
incompatibility, or feature incompatibility.