Installation Guide
Table Of Contents
- Welcome
- Audience
- Related Documentation
- FCC Notice
- RF Statements
- EMC and Safety Statements
- 1. Introduction
- 2. Installing Components and Troubleshooting
- 3. Pole Mount Installation
- 4. Pad Mount Installation
- Introduction
- Required Tools
- Installation Location
- Preparing the Transformer Pad
- Preparing for Installation
- Performing the Installation
- Extend Pad Mounting Bracket
- Attach Pad Mounting Bracket to Lifting Nut
- Attach Conduit Housing to Pad Mounting Bracket
- Insert Conduit Thread into Conduit Housing
- Attach ECN to Pad Mounting Bracket
- Secure ECN to Pad Mounting Bracket
- Connect the ECN to Power and the Network
- Close and Lock the Conduit Housing
- Complete the Installation
- Verifying Successful Installation
- 5. Field Replacement for an ECN 7000 Series Device
- A. ECN 7000 Series Specifications
- B. Safety and High-Voltage Warnings
- C. ESD and Battery Warnings
ECN 7000 Series Hardware Guide 7
Figure 4 shows the relationships between the main processor and the backplane.
Some of the functionality is provided by system cards, and the rest is provided by
expansion cards.
Main Processor
USB Hub
EV-DO
Modem
Expansion
Card
Expansion
Card
Broadband
USB/Serial
USB/Serial
USB/Serial
USB/Serial
Battery
Mgmt
PLC
Transceiver
PLC
Transceiver
Expansion Card
Ethernet
Ethernet USB Hub
USB Hub
Free USB
Port
Free USB
Port
Figure 4. ECN Main Board Architecture
Power Management
The ECN main board includes the power supply for the ECN unit, as well as for
the system cards and expansion cards. To maintain data integrity, the ECN
includes several watchdog and reset functions.
Main Power Supply
The ECN power supply is capable of operating on any phase of a 3-wire 120/240
V
AC
or 120/208 V
AC
network, making it compatible with network and non-network
transformers. The power can provide up to 30 W of continuous power, which is
ideal for RF applications where low radiated emissions are critical.
The main component of the power supply is located at the top of the ECN main
board, where the Faraday cage can provide adequate ventilation to prevent
excessive heating of the expansion cards.
Power-Up Function
On power-up, the ECN unit is held in reset by hardware watchdog circuitry until
the power supply stabilizes at its operating threshold. This function provides a