Edge Control Node 7000 Series Installation Guide 17
Figure 7. Attach the Conduit Housing to the Pad Mounting Bracket
Insert Conduit Thread into Conduit Housing
To protect the electrical and network cabling as it enters the Pad Mounting
Bracket Conduit Housing, insert a Conduit Thread unit into one of the available
holes in the bottom of the Conduit Housing. The Conduit Thread should
accommodate the locking nut for the conduit and the radius of one or more cable
bundles. The Conduit Housing provides three cutouts for conduits; at least one of
these should be precut to allow for insertion of the electrical and network cabling.
Insert the Conduit Thread into the Conduit Housing, as shown in
Figure 8 on
page
18. You can perform this step prior to field installation.