Application Guide

If your Eccotemp-L10 will not ignite, please review the following troubleshooting guide.
1. Check your propane tank to determine if you are out of gas and check your batteries to see if
they are properly installed. If your batteries are not new, try another set. When checking your
batteries, if you encounter corrosion, gently clean the connections with a wire brush and install
a fresh set. Be careful when doing this as battery acid is extremely harmful and poisonous.
2. Disconnect the incoming water line. There is a screen immediately inside of the incoming
water pipe that may have clogged over time and is reducing the water flow and water pressure.
3. After following these steps, test to see if the water heater is working.
4. If possible, disconnect the plumbing from the outgoing water connection and try to operate
the water heater to determine if your plumbing is the issue.
You need to have a minimum of 20 pounds per square inch of water pressure to activate and
sustain operation of the L10 water heater. If you cannot achieve and maintain adequate water
pressure, your water heater will function erratically or not at all. If you have low pressure that is
near adequate, please follow the link below to access instructions on increasing your L10's
sensitivity to water
pressure:https://eccotemp.zendesk.com/attachments/token/vkovnpzfcoips4n/?name=Pressur
e+Adjustment+Guide.pdf