Venting
The installation of venting must
comply with national codes, local
codes, and the vent manufacturer’s
instructions. Owner must refer to
vent manufacturer’s instructions
and specications. Z-Flex
information can be found at www.
novaex.com, please refer to page
19 for additional links.
The water heater must be vented
to the outdoors as described in
these instructions. DO NOT connect
this water heater to an existing
Vent or Chimney, it must be vented
separately from all other appliances.
All vent components (adapters,
pipe, elbows, terminals, etc.) should
be UL 1738 Certied Stainless Steel 
Venting Material (e.g. AL29-4C).
The specied vent termination must
be used. The termination should be
a 90° elbow type with screen.
(Refer to page 19).
Use a vent pipe with an 
antidisconnection structure.
The use of a High Temperature
Silicone (500’ F) may be required
to seal vent connections. To
prevent accidental gas exhaust
leakage, apply a 1/4” wide bead
approximately 1/4” from the end
and another bead against the joint
side of the stop bead.
Follow vent manufacturer’s
installation instructions.
The unit can be vented either
horizontally or vertically.
Vent pipe runs must be adequately
supported along both horizontal
and vertical runs.
The maximum recommended
unsupported span should be no
more than ve (5) feet. Support
isolation hanging bands should
be used. DO NOT use wire. (See
diagram below).
 DANGER: Failure 
to install the vent 
adapter and properly 
vent the water heater 
to the outdoors as
outlined in the 
Venting section of 
this manual will result 
in unsafe operation 
of the water heater 
causing death, serious 
injury, explosion, or 
re. To avoid the risk 
of re, explosion,or 
asphyxiation from 
carbon monoxide, 
NEVER operate the 
water heater unless it
is properly vented 
and has adequate 
air supply for proper 
operation as outlined
in the Venting section 
of this manual.
 WARNING: Use
UL approved Category 
III Stainless Steel vent 
material only. No 
other vent material is 
permitted.
Owner must refer to 
vent manufacturer’s 
instructions and 
specications. Z-Flex
information can 
be found at www.
novaex.com, see 
page 19 for additional 
links.
 WARNING: Refer 
to pages 17-18 for 
clearances to
combustible material.
Installing the 45-HI water heater
Venting Through Closed Spaces
If the vent piping passes through a closed space, wrap the vent pipe with inammable insulation material 
that is at least 3/4” thick. DO NOT let the insulation material make contact with ammable materials. A 
minimum clearance of 6” between the vent pipe and ceiling should be maintained. Follow local codes.
For maintenance and inspection purposes, the
following holes are required to be made:
• Two (2) inspection openings that allow access to venting. One
  ( 1) of these openings should be close to where the vent pipe
  enters the ceiling. The other opening should be near the vent 
termination.
• A ventilation hole with a 16 sq. in. opening should be made at 
least every 10 feet.
NOTICE : Vent pipes must be completely insulated with 
inammable material when installed in alcoves, closets, and garages and must not touch any ammable 
material.