Setting the Temperature:
The Eccotemp FVI12-LP/NG models are MANUAL TEMPERATURE CONTROLLED units. This means
that the temperature must be adjusted on the face plate of the unit and not at the output source
(sink or shower).
When you try to mix hot water with cold at the output source, the heater will shut down because
as you mix in the cold water, you are decreasing the amount of required water pressure to keep
the unit activated. The FVi12 is a pressure activated unit and should maintain at least 40-60 PSI of
water pressure. When cold water is added, the pressure drops below the activation point.
Manual Temperature Control: You must adjust the
temperature manually each time you use the unit. The
temperature must be adjusted according to the amount
of applications being used at the same time due to the
uctuation of pressure.
NOTICE: If inlet water temperature is high, and set
temperature is low, the actual temperature might be higher
than the set temperature, and viceversa..
DANGER: There is a hot water
scald potential if the temperature
is set too high. Households with
small children, disabled, or elderly
persons may require a 120°F or
lower temperature setting to
prevent contact with HOT water.
Output temperature of water is regulated by
setting the temperature on the front of the unit.
Safety factors should be considered when
selecting the water temperature.
Water temperature above 120°F can cause severe
burns or death from scalding. The thermostat is
adjusted to its lowest temperature position when
shipped from the factory.
Be sure to read and follow the warnings outlined
in this manual and on the label located on the
water heater. Mixing valves are available for
reducing point of use water temperature by
mixing hot and cold water in branch water lines.
Procedures for adjusting the thermostat for
energy e cient operation at the minimum
water temperature setting consistent with the
consumers needs.
Contact a licensed plumber or the local plumbing
authority for further information. See page 4 for
details.
Water Temperature
120°F
125°F
130°F
135°F
140°F
145°F
150°F
155°F
Time To Produce a Serious Burn
More than 5 minutes
1 1/2to 2 minutes
About 30 seconds
About 10 seconds
Less than 5 seconds
Less than 3 seconds
About 1 1/2 seconds
About 1 second
Table courtesy of Shriners Burn Institute
Automatic Temperature Control: The unit will self-adjust
temperature according to what is being requested of
it at the output water source (sink or shower). It also will
regulate the temperature automatically according to
how many applications are being used at the same time.
WARNING: Should overheating occur or the gas supply fail to shut o , turn o the
manual gas control valve to the water heater.
NOTICE: If the BATH control ls turned on, the temperature setting on the MAIN control
cannot be changed. The BATH control(s) will always have PRIORITY over the MAIN control.