User's Manual

51 | P a g e www.eccel.co.uk
Command description
Argument
Size
Value
Description
Command ID
1
0x9D
ICODE_READ_EPC
Response description
ACK
1
0x00
Command ID
1
0x9D
ICODE_READ_EPC
EPC information
12
X
Please refer to the NXP documentation for more information.
Example:
HOST=>READER: 0x9D – ICODE_READ_EPC
READER=>HOST: 0x00 – ACK byte
0x9D – related command code ICODE_READ_EPC
0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 – result bytes
3.6.15 Get NXP System Information (0x9E)
This command retrieves the NXP system information value from the TAG. No arguments are required. The
ACK response contains bytes with the NXP system information. Please refer to the NXP documentation for
more information.
Command description
Argument
Size
Value
Description
Command ID
1
0x9E
ICODE_GET_NXP_SYSTEM_INFORMATION
Response description
ACK
1
0x00
Command ID
1
0x9E
ICODE_GET_NXP_SYSTEM_INFORMATION
System
information
X XXX System information bytes
Example:
HOST=>READER: 0x9E – ICODE_GET_NXP_SYSTEM_INFORMATION
READER=>HOST: 0x00 – ACK byte
0x9E – related command code
ICODE_GET_NXP_SYSTEM_INFORMATION
0x0F 0x04 0x8F 0x7F 0x0A 0x01 0x24
0x16 0xE0 0x00 0x00 0x33 0x03 0x02 – result bytes