2. Electrical specification
2.1 Absolute maximum ratings
Stresses beyond the absolute maximum ratings listed in the table below may cause permanent damage to the
device. These are stress ratings only, and do not refer to the functional operation of the device that should
follow the recommended operating conditions.
Symbol
Parameter
Min
Max
Unit
T
S
Storage temperature
-
40
+125
°C
T
A
Ambient temperature
-
40
+85
°C
V
DDMAX
Supply voltage
4.5
5.5
V
Table 2-1. Absolute maximum ratings
2.2 Operating conditions
Symbol
Parameter
Min
Typ
Max
Unit
T
S
Operating temperature
-
25
25
+85
°C
H
Humidity
5
60
95
%
V
DD
Supply voltage
4.75
5
5.
25
V
Table 2-2. Operating conditions
2.3 DC characteristics (V
DD
= 5 V, T
S
= 25 °C)
Symbol
Parameter
Min
Typ
Max
Unit
V
ORS485
V output RS
485
(RS
485
_TX pin)
-
5
-
V
V
IRS485
V input RS
485
(RS
485
_RX pin)
-
7
-
+
1
2
V
Table 2-3. DC characteristics
2.4 Current consumption (5V input)
Symbol
Parameter
Typ
Max
Unit
I
PN_RFOFF
RF field off 20 mA
I
PN_RFON
RF field on 60
1
250
2
mA
Table 2-4. Current consumption
1
Dedicated NTag216 tag may increase current consumption up to 90mA and value depends on distance and
location between tag and antenna (higher consumption is when tag is closer to the antenna).
2
Any metal object located in electromagnetic flux will increase current consumption.