15 | P a g e www.eccel.co.uk
0x0F
-
JCOP
0x10 – MIFARE Mini
0x21 – ICODE Sli
0x22 – ICODE Sli-S
0x23 – ICODE Sli-L
0x24 – ICODE Slix
0x25 – ICODE Slix-S
0x26 – ICODE Slix-X
0x27 – ICODE Slix2
0x28 – ICODE DNA
TAG parameter 1 X
SAK
-
byte for
MIFARE
family tags
DSFID - byte for ICODE family tags
UID
N
X
UID bytes. Max length is 8.
Example:
HOST=>READER: 0x03 – GET_TAG_UID
0x00 – TAG idx
READER=>HOST: 0x00 - ACK byte
0x03 - related command code GET_TAG_UID
0x01 – MIFARE tag type
0x20 – tag parameter:
SAK byte for MIFARE family tags
DSFID byte for ICODE family tags
0x74 0x54 0x12 0x65 – tag UID bytes
5.1.6 Activate TAG (0x04)
The command activates a TAG after the discovery loop if more than one TAG is detected.
Command description
Argument
Size
Value
Description
Command ID
1
0x04
ACTIVATE_TAG
TAG idx 1 X
TAG
index in module memory, must me less than number of tags
reported by GET_TAG_COUNT command
Response
description
ACK
1
0x00
Command ID
1
0x04
ACTIVATE_TAG
Example:
HOST=>READER: 0x04 – ACTIVATE_TAG
0x00 – TAG idx
READER=>HOST: 0x00 - ACK byte
0x04 - related command code ACTIVATE_TAG