Installation Instructions
Technical characteristics
Transponder protocol
EPC class Gen2 (ISO 18000-6-c)
UHF RFID antenna interface
Antenna connection
one internal antenna (up to 20 cm read range)
3 x SMA connector (50 Ohm)
Transmitting Power
Frequency area
max. 0.5 W configurable
860 MHz ... 960 MHz (depending on specific reader)
Interfaces
Performance
Max.Operating Distance
•
RF-R200 (PoE) Ethernet (TCP/IP) 10/100 Mbit/s; Full Spec. 802.3
•
RF-R200 (module); RS 323 (serial), USB
Up to 2 m, depending on transponder & environmental conditions
Protocol Modi
•
Host Mode
•
Notification Mode (Ha-VIS RFID RF-R200 (PoE))
•
Scan Mode (Ha-VIS RFID RF-R200 (module))
•
Buffered read mode
Power Supply
Power supply
12 V ... 24 V DC
Power consumption
max. 7 W
Design features
145x85x27
IP 30
DIN rail mounting kit (optional accessories)
-25 °C ... +55 °C (module)
-25 °C ... +85 °C
Dimensions (W x H x D)
Degreeofprotectionacc.toDIN
60 529 Installation on DIN rail
Environmental conditions
Operating temperature
Storage temperature
Relative humidity
5 % ... 95 % (non-condensing)
Vibration
Shock
EN 60 068-2-6 10 Hz ... 150 Hz: 0.075 mm / 1 g
EN 60 068-2-27 Acceleration: 30 g