2D Area Imager Bar Code Scanner CONFIGURATION GUIDE For EC IG-2D, EC IG-2DBT, EC 7110-2D models
@ Copyright 2013 This manual is copyrighted, with all right reserved. Under the copyright laws, this manual may not, in whole or in part, be copied, photocopied, reproduced, translated or converted to any electronic medium or machine readable form without prior written consent of maker.
Table of Contents Chapter 1 General Description .............................................. 1 Chapter 2 Introduction ......................................................... 2 Chapter 3 User Preferences .................................................. 4 RETURN TO DEFAULT ............................................................................... 4 PARAMETER SCANNING ..................................................................
IMAGE CROPPING ..................................................................................... 21 CROP TO PIXEL ADDRESSES ................................................................ 22 IMAGE RESOLUTION ................................................................................ 23 JPEG IMAGE OPTIONS ............................................................................. 24 JPEG QUALITY AND SIZE VALUE ............................................
IGNORE UNKNOWN CHARACTERS ...................................................... 41 ASCII CHARACTER SET FOR SERIAL HOSTS ................................... 42 Chapter 6 USB Interface ...................................................... 47 USB HOST PARAMETERS ....................................................................... 48 NATIVE API (SNAPI) STATUS HANDSHAKING ...................................
CODABAR (NW - 7) .................................................................................. 106 MSI ............................................................................................................... 109 POSTAL CODES ....................................................................................... 113 GS1 DATABAR .......................................................................................... 117 COMPOSITE .......................
SLEEP MODE ............................................................................................ 147 BATCH MODE ........................................................................................... 148 FIRMWARE VERSION : ........................................................................... 149 APPENDIX A : STANDARD DEFAULT PARAMETERS ..................... 150 APPENDIX B : SYMBOL CODE IDENTIFIERS ....................................
Chapter 1 General Description Thank you for purchasing this barcode scanner with an advanced and versatile decoder. The decoder works with variety of barcode types, reading devices, and computer interfaces. It discriminates over twenty different symbologies automatically. This menu provides an easy way to configure the decoding options and interface selections by scan- ning bar codes listed in the menu.
Chapter 2 Introduction This document provide an easy way to program the decoding options and interface selections by scanning bar codes listed in this guide. Important Notice 1. This document is in A5 size. Please check your printing setting before printing it out. 2. When printing barcodes for programming, the use of a high-resolution laser printer is strongly suggested for the best scan result. 3. The settings shall be updated periodically without prior notice.
Default Factory Device Settings User Preferences Parameter Default Set Default Parameter All Defaults Parameter Scanning Enable Beeper Tone Medium Beeper Volume High Beeper Duration Long Trigger Mode Power Mode Handheld/Hands-free Scanner Level Scan Module Presentation Handheld/Hands-free Scanner Low Power Scan Module Low Power Time Delay to Low Power Mode 1.0 Sec Decode Session Timeout 9.9 Sec Timeout Between Decodes, Same Symbol 0.
Chapter 3 User Preferences RETURN TO DEFAULT 1. For Desktop and Fixed mount default : (EC 7110-2D) You can scan this programming code to restore the scanner’s parameters to factory default configuration. Remark: these default setting are associated to configuration in Chapter 3 to Chapter 8. 2.
3. For Bluetooth’s default: (EC IG-2DBT) You can scan this programming code to restore the Bluetooth’s parameters to factory default configuration. Remark: this default setting is associated to configuration in Chapter 9, no effect for wired models.
BEEPER TONE To select a decode beep frequency (tone); scan the Low Frequency, Medium Frequency, or High Frequency bar code.
BEEPER VOLUME To select a beeper volume, scan the Low Volume, Medium Volume, or High Volume bar code. Low Volume Medium Volume < High Volume > BEEPER DURATION To select the duration for the beeper, scan one of the following bar codes.
TRIGGER MODES Level Mode - A trigger event activates decode processing, which continues until the trigger event ends, a valid decode, or the decode session time-out is reached. This scan mode is not available for scan module. Presentation Mode - When the device detects an object in its field of view it triggers and attempts to decode. The range of object detection does not vary under normal lighting conditions. This applies to decode mode only. In this mode the unit does not enter its sleep state.
POWER MODE This parameter determines whether or not power remains on after a decode attempt. In low power mode, the decoder enters into a low power consumption mode to preserve battery life after each decode attempt. In continuous power mode, power remains on after each decode attempt.
TIME DELAY TO LOW POWER MODE This parameter sets the time the decoder remains active after decoding. The decoder wakes upon trigger pull or when the host attempts to communicate with the decoder. Note: 1. This parameter only applies when Power Mode is set to Low Power. 2. This setting is not available for scan module since it is always in presentation mode and its power is continuous on.
DECODE SESSION TIMEOUT This parameter sets the maximum time decode processing continues during a scan attempt. It is programmable in 0.1 second increments from 0.5 to 9.9 seconds. The default timeout is 9.9 seconds. To set a Decode Session Timeout, scan the bar code below. Next, scan two numeric bar codes from Appendix D, Numeric Barcodes that correspond to the desired on time. Single digit numbers must have a leading zero. For example, to set a Decode Session Timeout of 0.
BEEP AFTER GOOD DECODE Scan a bar code below to select whether or not the decoder issues a beep signal after a good decode. If selecting Do Not Beep after Good Decode, beeper signals are issued during parameter menu scanning and to indicate error conditions.
Chapter 4 Imager Preferences Lists the defaults for imaging preferences options. To change the default values, scan the appropriate bar codes in this guide.
Signature Capture Bits per Pixel (BPP) 8 BPP Signature Capture Width 400 Signature Capture Height 100 Signature Capture JPEG Quality 65 Video View Finder Disable Video View Finder Image Size 1700 bytes The parameters in this section control image capture characteristics. Image capture occurs in all modes of operation, including decode, video, and snapshot.
SNAPSHOT MODE Use Snapshot Mode to capture a high-quality image and transmit it to the host. To temporarily enter this mode scan the Snapshot Mode bar code. While in this mode the decoder blinks the orange LED at 1-second intervals to indicate it is not in standard operating (decode) mode. In Snapshot Mode, the decoder turns on the laser aiming pattern to highlight the area to be captured in the image. The next trigger event instructs the decoder to capture a high quality image and transmit it to the host.
DECODING AUTO EXPOSURE Select Enable Auto exposure to allow the device to control gain settings and exposure (integration) time to best capture an image for the selected operation mode. Select Disable Auto exposure to manually adjust the gain and exposure time. This option is only recommended for advanced users with difficult image capture situations.
DECODE AIMING PATTERN This parameter only applies when in Decode Mode. Select Enable Decode Aiming Pattern to project the aiming pattern during bar code capture, or Disable Decode Aiming Pattern to turn the aiming pattern off. < Enable Decode Aiming Pattern > (Default for handheld scanners.) (Default for desktop and fixed mount module.
IMAGE CAPTURE ILLUMINATION Selecting Enable Image Capture Illumination causes the decoder to flash on every image capture. Select Disable Illumination to prevent the decoder from using artificial illumination. Enabling illumination usually results in superior images. The effectiveness of the illumination decreases as the distance to the target increases.
EXPOSURE TIME This parameter is only available when Image Capture Auto exposure is disabled. Exposure Time controls the amount of time the CCD is allowed to collect light, much like the shutter speed for a camera. Generally, the brighter the environment is, the shorter the exposure time would be. Set the manual exposure time to one of the following values: 5 ms, 10 ms, 15 ms, 20 ms, 25 ms, or 30 ms.
SNAPSHOT MODE TIMEOUT This parameter sets the amount of time the decoder remains in Snapshot Mode. The decoder exits Snapshot Mode upon a trigger event, or when the Snapshot Mode Timeout elapses. To set this timeout value, scan the bar code below followed by a bar code from Appendix D, Numeric Bar Codes. The default value is 0 which represents 30 seconds; values increment by 30. For example, 1 = 60 seconds, 2 = 90 seconds, etc.
IMAGE CROPPING This parameter crops a captured image. If Disable Image Cropping is selected, the full 640 x 480 pixels are presented. If Enable is selected, the decoder crops the image to the pixel addresses set in Crop to Pixel Addresses.
CROP TO PIXEL ADDRESSES If Enable Image Cropping is selected, set the pixel addresses from (0, 0) to (639,479) to crop to. Columns are numbered from 0 to 639, rows from 0 to 479. Specify four values for Top, Left, Bottom, and Right, where Top and Bottom correspond to row pixel addresses, and Left and Right correspond to column pixel addresses.
IMAGE RESOLUTION This option alters image resolution before compression. Multiple pixels are combined to one pixel, resulting in a smaller image containing the original content with reduced resolution.
JPEG IMAGE OPTIONS JPEG images can be optimized for either size or for quality. Scan the Quality Selector bar code to enter a quality value; the decoder then selects the corresponding image size. Scan the Size Selector bar code to enter a size value; the decoder then selects the best image quality.
IMAGE FILE FORMAT SELECTOR Select an image format appropriate for the system (BMP, TIFF, or JPEG). The decoder stores captured images in the selected format. BMP File Format < JPEG File Format > TIFF File Format BITS PER PIXEL Select the number of significant bits per pixel (BPP) to use when capturing an image. Select 1BPP for a black and white image, 4BPP to assign 1 of 16 levels of grey to each pixel, or 8BPP to assign 1 of 256 levels of grey to each pixel.
VIDEO VIEW FINDER Select Enable Video View Finder to project the video view finder while in Image Mode, or Disable Video View Finder to turn the video view finder off. < Disable Video View Finder > Enable Video View Finder TARGET VIDEO FRAME SIZE Select the number of 100-byte blocks to be transmitted per second. Selecting a smaller value allows more frames to be transmitted per second but reduces video quality; selecting a larger value increases video quality but slows transmission.
Chapter 5 Serial Interface Introduction This chapter describes how to set up the decoder with a serial host. The serial interface is used to connect the decoder to point-of sale devices, host computers, or other devices with an available serial port (e.g. com port). Note: The decoder uses TTL signal levels, which interface with most system architectures. System architectures that use RS-232C signal levels require a conversion circuitry.
SERIAL PARAMETER DEFAULTS The table below lists the defaults for serial host parameters. To change any option, scan the appropriate bar code(s) provided in the Serial Host Parameters section. Note: See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters.
SERIAL HOST TYPES To select a serial host interface, scan one of the following bar codes. Enable Serial Host (Standard RS232) *Scanning Enable Serial Host (No Variant) activates the serial driver, but does not change port settings (e.g., parity, data bits, handshaking). Selecting another serial host type bar code changes these settings.
BAUD RATE Baud rate is the number of bits of data transmitted per second. Set the decoder's baud rate to match the baud rate setting of the host device. Otherwise, data may not reach the host device or may reach it in distorted form.
PARITY A parity check bit is the most significant bit of each ASCII coded character. Select the parity type according to host device requirements. Select Odd parity and the parity bit value is set to 0 or 1, based on data, to ensure that an odd number of 1 bits are contained in the coded character. Select Even parity and the parity bit value is set to 0 or 1, based on data, to ensure that an even number of 1 bits are contained in the coded character. Select None when no parity bit is required.
STOP BIT SELECT The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream. The number of stop bits selected (one or two) depends on the number the receiving terminal is programmed to accommodate. Set the number of stop bits to match host device requirements.
CHECK RECEIVE ERRORS Select whether or not the parity, framing, and overrun of received characters are checked. The parity value of received characters is verified against the parity parameter selected above.
HARDWARE HANDSHAKING The data interface consists of a serial port designed to operate either with or without the hardware handshaking lines, Request to Send (RTS), and Clear to Send (CTS). If Standard RTS/CTS handshaking is not selected, scan data is transmitted as it becomes available. If Standard RTS/CTS handshaking is selected, scan data is transmitted according to the following sequence: The decoder reads the CTS line for activity.
decoder issues an error indication and discards the data. RTS/CTS Option 3: When Option 3 is selected, the decoder asserts RTS prior to any data transmission, regardless of the state of CTS. The decoder waits up to Host Serial Response Time-out (default) for CTS to be asserted. If CTS is not asserted during this time, the decoder issues an error indication and discards the data. The decoder de-asserts RTS when transmission is complete.
SOFTWARE HANDSHAKING This parameter offers control of the data transmission process in addition to, or instead of, that offered by hardware handshaking. There are five options. If Software Handshaking and Hardware Handshaking are both enabled, Hardware Handshaking takes precedence. None: When this option is selected, data is transmitted immediately. No response is expected from host.
< None > ACK/NAK ENQ ACK/NAK with ENQ XON/XOFF 37
HOST SERIAL RESPONSE TIME-OUT This parameter specifies how long the decoder waits for an ACK, NAK, or CTS before determining that a transmission error has occurred. This only applies when in one of the ACK/NAK Software Handshaking modes, or RTS/CTS Hardware Handshaking option. < Minimum: 2 Sec > Low: 2.5 Sec Medium: 5 Sec High: 7.5 Sec Maximum: 9.
RTS LINE STATE This parameter sets the idle state of the Serial Host RTS line. Scan a bar code below to select Low RTS or High RTS line state. < Host: Low RTS > Host: High RTS BEEP ON When this parameter is enabled, the decoder issues a beep when a character is detected on the serial line. is issued to gain a user's attention to an illegal entry or other important event.
INTERCHARACTER DELAY This parameter specifies the intercharacter delay inserted between character transmissions.
IGNORE UNKNOWN CHARACTERS Unknown characters are characters the host does not recognize. When Send Bar Codes with Unknown Characters is selected, all bar code data is sent except for unknown characters, and no error beeps sound on the decoder. When Do Not Send Bar Codes With Unknown Characters is selected, bar code data is sent up to the first unknown character and then an error beep will sound on the decoder.
ASCII CHARACTER SET FOR SERIAL HOSTS The values in the table below can be assigned as prefixes or suffixes for ASCII character data transmission.
1021 $U NAK 1022 $V SYN 1023 $W ETB 1024 $X CAN 1025 $Y EM 1026 $Z SUB 1027 %A ESC 1028 %B FS 1029 %C GS 1030 %D RS 1031 %E US 1032 Space Space 1033 /A ! 1034 /B " 1035 /C # 1036 /D $ 1037 /E % 1038 /F & 1039 /G ‘ 1040 /H ( 1041 /I ) 1042 /J * 1043 /K + 1044 /L , 1045 - - 1046 . .
1050 2 2 1051 3 3 1052 4 4 1053 5 5 1054 6 6 1055 7 7 1056 8 8 1057 9 9 1058 /Z : 1059 %F ; 1060 %G < 1061 %H = 1062 %I > 1063 %J ? 1064 %V @ 1065 A A 1066 B B 1067 C C 1068 D D 1069 E E 1070 F F 1071 G G 1072 H H 1073 I I 1074 J J 1075 K K 1076 L L 1077 M M 1078 N N 44
1079 O O 1080 P P 1081 Q Q 1082 R R 1083 S S 1084 T T 1085 U U 1086 V V 1087 W W 1088 X X 1089 Y Y 1090 Z Z 1091 %K [ 1092 %L \ 1093 %M ] 1094 %N ^ 1095 %O _ 1096 %W ` 1097 +A a 1098 +B b 1099 +C c 1100 +D d 1101 +E e 1102 +F f 1103 +G g 1104 +H h 1105 +I i 1106 +J j 1107 +K k 45
1108 +L l 1109 +M m 1110 +N n 1111 +O o 1112 +P p 1113 +Q q 1114 +R r 1115 +S s 1116 +T t 1117 +U u 1118 +V v 1119 +W w 1120 +X x 1121 +Y y 1122 +Z z 1123 %P { 1124 %Q | 1125 %R } 1126 %S ~ 1127 Undefined 7013 ENTER 46
Chapter 6 USB Interface Introduction This chapter describes how to set up the decoder with a USB host. The decoder connects directly to a USB host, or a powered USB hub, and is powered by it. No additional power supply is required. Note: Most computer monitors allow scanning the bar codes directly on the screen. When scanning from the screen, be sure to set the document magnification to a level where the bar code can be seen clearly, and bars and/or spaces are not merging.
USB HOST PARAMETERS USB Device Type Select the desired USB device type. Note: When changing USB Device Types, the decoder automatically resets. The decoder issues the standard startup beep sequences.
* Note: Steps for activating CDC COM port emulation (USB virtual COM): 1. Execute the driver (installMOTCDC.exe). If you don’t have the driver, contact your distributor. 2. Connect the scanner USB cable to the host computer. The scanner would give a “Do Re Mi” melody when powered on. 3. Read the “CDC COM Port Emulation” barcode to set up the interface. 4. On the computer, check Device Manager to see if the computer successfully detects the scanner as “Bar Code Scanner.
NATIVE API (SNAPI) STATUS HANDSHAKING After selecting a SNAPI interface as the USB device type, select whether to enable or disable status handshaking. < Enable SNAPI Status Handshaking > Disable SNAPI Status Handshaking USB COUNTRY KEYBOARD TYPES (COUNTRY CODES) Scan the bar code corresponding to the keyboard type. This setting applies only to the USB HID Keyboard Emulation device. Note: When changing USB country keyboard types the decoder automatically resets.
French Canadian Windows 2000/XP French Canadian Windows 95/98 Spanish Windows Italian Windows Swedish Window UK English Windows Japanese Windows (ASCII) 51 Portuguese-Brazilian Windows
USB KEYSTROKE DELAY This parameter sets the delay, in milliseconds, between emulated keystrokes. Scan a bar code below to increase the delay when hosts require a slower transmission of data. < No Delay > Medium Delay (20 msec) Long Delay (40 msec) USB CAPS LOCK OVERRIDE This option applies only to the HID Keyboard Emulation device. When enabled, the case of the data is preserved regardless of the state of the caps lock key.
USB IGNORE UNKNOWN CHARACTERS This option applies only to the HID Keyboard Emulation device and IBM device. Unknown characters are characters the host does not recognize. When Send Bar Codes With Unknown Characters is selected, all bar code data is sent except for unknown characters, and no error beeps sound. When Do Not Send Bar Codes With Unknown Characters is selected, for IBM devices, bar codes containing at least one unknown character are not sent to the host, and an error beep sounds.
USB KEYBOARD FN 1 SUBSTITUTION This option applies only to the USB HID Keyboard Emulation device. When enabled, this allows replacement of any FN 1 characters in an EAN 128 bar code with a Key Category and value chosen by the user. Enable < Disable > FUNCTION KEY MAPPING ASCII values under 32 are normally sent as a control-key sequence. When this parameter is enabled, the keys in bold are sent in place of the standard key mapping.
SIMULATED CAPS LOCK When enabled, the decoder inverts upper and lower case characters on the bar code as if the Caps Lock state is enabled on the keyboard. This inversion is done regardless of the current state of the keyboard’s Caps Lock state. < Disable Simulated Caps Lock > Enable Simulated Caps Lock CONVERT CASE When enabled, the decoder converts all bar code data to the selected case.
ASCII CHARACTER SET FOR USB Prefix/ Suffix Value USB Prefix/Suffix Values Full ASCII Code 39 Encode Character Keystroke 1000 %U CTRL 2 1001 $A CTRL A 1002 $B CTRL B 1003 $C CTRL C 1004 $D CTRL D 1005 $E CTRL E 1006 $F CTRL F 1007 $G CTRL G 1008 $H 1009 $I 1010 $J CTRL 1 H/BACKSPACE CTRL I/HORIZONTAL 1 TAB CTRL J 1011 $K CTRL K 1012 $L CTRL L 1013 $M CTRL M/ENTER 1014 $N CTRL N 1015 $O CTRL O 1016 $P CTRL P 1017 $Q CTRL Q 1018 $R CTRL R 1019 $S CTR
1023 $W CTRL W 1024 $X CTRL X 1025 $Y CTRL Y 1026 $Z CTRL Z 1027 %A CTRL [/ESC 1028 %B CTRL \ 1029 %C CTRL ] 1030 %D CTRL 6 1031 %E CTRL 1032 Space Space 1033 /A ! 1034 /B “ 1035 /C # 1036 /D $ 1037 /E % 1038 /F & 1039 /G ‘ 1040 /H ( 1041 /I ) 1042 /J * 1043 /K + 1044 /L , 1045 - - 1046 . .
1052 4 4 1053 5 5 1054 6 6 1055 7 7 1056 8 8 1057 9 9 1058 /Z : 1059 %F ; 1060 %G < 1061 %H = 1062 %I > 1063 %J ? 1064 %V @ 1065 A A 1066 B B 1067 C C 1068 D D 1069 E E 1070 F F 1071 G G 1072 H H 1073 I I 1074 J J 1075 K K 1076 L L 1077 M M 1078 N N 1079 O O 1080 P P 58
1081 Q Q 1082 R R 1083 S S 1084 T T 1085 U U 1086 V V 1087 W W 1088 X X 1089 Y Y 1090 Z Z 1091 %K [ 1092 %L \ 1093 %M ] 1094 %N ^ 1095 %O _ 1096 %W ` 1097 +A a 1098 +B b 1099 +C c 1100 +D d 1101 +E e 1102 +F f 1103 +G g 1104 +H h 1105 +I i 1106 +J j 1107 +K k 1108 +L l 1109 +M m 59
1110 +N n 1111 +O o 1112 +P p 1113 +Q q 1114 +R r 1115 +S s 1116 +T t 1117 +U u 1118 +V v 1119 +W w 1120 +X x 1121 +Y y 1122 +Z z 1123 %P { 1124 %Q | 1125 %R } 1126 %S ~ The keystroke in bold is sent only if the “Function Key Mapping” is enabled. Otherwise, the unbolded keystroke is sent.
USB ALT Key Character Set ALT Keys Keystroke 2064 ALT 2 2065 ALT A 2066 ALT B 2067 ALT C 2068 ALT D 2069 ALT E 2070 ALT F 2071 ALT G 2072 ALT H 2073 ALT I 2074 ALT J 2075 ALT K 2076 ALT L 2077 ALT M 2078 ALT N 2079 ALT O 2080 ALT P 2081 ALT Q 2082 ALT R 2083 ALT S 2084 ALT T 2085 ALT U 2086 ALT V 2087 ALT W 2088 ALT X 2089 ALT Y 2090 ALT Z 61
USB GUI Key Character Set GUI Key Keystroke 3000 Right Control Key 3048 GUI 0 3049 GUI 1 3050 GUI 2 3051 GUI 3 3052 GUI 4 3053 GUI 5 3054 GUI 6 3055 GUI 7 3056 GUI 8 3057 GUI 9 3065 GUI A 3066 GUI B 3067 GUI C 3068 GUI D 3069 GUI E 3070 GUI F 3071 GUI G 3072 GUI H 3073 GUI I 3074 GUI J 3075 GUI K 3076 GUI L 3077 GUI M 3078 GUI N 3079 GUI O 3080 GUI P 62
3081 GUI Q 3082 GUI R 3083 GUI S 3084 GUI T 3085 GUI U 3086 GUI V 3087 GUI W 3088 GUI X 3089 GUI Y 3090 GUI Z Note: GUI Shift Keys - The Apple™ iMac keyboard has an apple key on either side of the space bar. Windows-based systems have a GUI key to the left of the left ALT key, and to the right of the right ALT key.
USB F Key Character Set F Keys Keystroke 5001 F1 5002 F2 5003 F3 5004 F4 5005 F5 5006 F6 5007 F7 5008 F8 5009 F9 5010 F10 5011 F11 5012 F12 5013 F13 5014 F14 5015 F15 5016 F16 5017 F17 5018 F18 5019 F19 5020 F20 5021 F21 5022 F22 5023 F23 5024 F24 64
USB Numeric Keypad Character Set Numeric Keypad Keystroke 6042 * 6043 + 6044 undefined 6045 - 6046 .
USB Extended Keypad Character Set Extended Keypad Keystroke 7001 Break 7002 Delete 7003 PgUp 7004 End 7005 Pg Dn 7006 Pause 7007 Scroll Lock 7008 Backspace 7009 Tab 7010 Print Screen 7011 Insert 7012 Home 7013 Enter 7014 Escape 7015 Up Arrow 7016 Down Arrow 7017 Left Arrow 7018 Right Arrow 66
Chapter 7 Symbologies Introduction This chapter describes symbology features and provides the programming bar codes for selecting these features. The device is shipped with the settings shown in the Symbology Default Table If the default values suit requirements, programming is not necessary. There are two ways to change a parameter value: Scan the appropriate bar codes in this guide. These new values replace the standard default values in memory.
SYMBOLOGY PARAMETER DEFAULTS Table below lists the defaults for all symbologies parameters. To change any option, scan the appropriate barcode(s) provided in the Symbologies Parameters section. Note: See Appendix A, Standard Default Parameters for all user preferences, hosts, and miscellaneous default parameters.
EAN-8/JAN-8 Extend Disable UCC Coupon Extended Code Disable Code 128 Code 128 Enable UCC/EAN-128 Enable ISBT 128 Enable Code 39 Code 39 Enable Trioptic Code 39 Disable Convert Code 39 to Code 32 (Italian Pharmacy Code) Disable Code 32 Prefix Disable Set Length(s) for Code 39 2 to 55 Code 39 Check Digit Verification Disable Transmit Code 39 Check Digit Disable Code 39 Full ASCII Conversion Disable Buffer Code 39 Disable Code 93 Code 93 Disable Set Length(s) for Code 93 4 to 55
Transmit Code 11 Check Digit(s) Disable Interleaved 2 of 5 (ITF) Interleaved 2 of 5 (ITF) Enable Set Lengths for I 2 of 5 14 I 2 of 5 Check Digit Verification Disable Transmit I 2 of 5 Check Digit Disable Convert I 2 of 5 to EAN 13 Disable Discrete 2 of 5 (DTF) Discrete 2 of 5 Disable Set Length(s) for D 2 of 5 12 Codabar (NW - 7) Codabar Disable Set Lengths for Codabar 5 to 55 CLSI Editing Disable NOTIS Editing Disable MSI MSI Disable Set Length(s) for MSI 4 to 55 MSI Check Digi
UK Postal Enable Transmit UK Postal Check Digit Enable Japan Postal Enable Australian Postal Enable Dutch Postal Enable Transmit US Postal Check Digit Enable RSS (Reduced Space Symbology) RSS 14 Enable RSS Limited Enable RSS Expanded Enable Convert RSS to UPC/EAN Disable Composite Composite CC-C Disable Composite CC-A/B Disable Composite TLC-39 Disable UPC Composite Mode Always Linked Composite Beep Mode Beep As Each Code Type is Decoded UCC/EAN Code 128 Emulation Mode for UCC/
Data Matrix Enable Maxicode Enable QR Code Enable Symbology-Specific Security Levels Redundancy Level 1 Security Level 1 Inter character Gap Size Normal Report Version Macro PDF Macro PDF Transmit/Decode Mode Symbols Pass through Mode Transmit Macro PDF Control Header Disable Escape Characters None Flush Macro PDF Buffer Abort Macro PDF Entry 72
UPC/EAN Enable/Disable UPC-A To enable or disable UPC-A, scan the appropriate barcode below. < Enable UPC-A > Disable UPC-A Enable/Disable UPC-E To enable or disable UPC-E, scan the appropriate bar code below.
Enable/Disable UPC-E1 UPC-E1 is disabled by default. To enable or disable UPC-E1, scan the appropriate bar code below. Note: UPC-E1 is not a UCC (Uniform Code Council) approved symbology. Enable UPC-E1 < Disable UPC-E1 > Enable/Disable EAN-8/JAN-8 To enable or disable EAN-8/JAN-8, scan the appropriate bar code below.
Enable/Disable EAN-13/JAN-13 To enable or disable EAN-13/JAN-13, scan the appropriate bar code below. < Enable EAN-13/JAN-13 > Disable EAN-13/JAN-13 Enable/Disable Bookland EAN To enable/disable Bookland EAN, scan the appropriate barcode below.
Decode UPC/EAN/JAN Supplementals Supplemental are bar codes appended according to specific format conventions (e.g., UPC A+2, UPC E+2, EAN 13+2). Six options are available. If Decode UPC/EAN/JAN Only With Supplemental is selected, UPC/EAN/JAN symbols without supplemental are not decoded. If Ignore Supplemental is selected, and the decoder is presented with a UPC/EAN/JAN with a supplemental, the UPC/EAN/JAN is decoded and the supplemental bar code is ignored.
Decode UPC/EAN/JAN Only With Supplemental < lgnore Supplemental > Auto discriminate UPC/EAN/JAN Supplemental Enable 378/379 Supplemental Mode Enable 978 Supplemental Mode Enable Smart Supplemental Mode 77
UPC/EAN/JAN Supplemental Redundancy With Auto discriminate UPC/EAN/JAN Supplemental selected, this option adjusts the number of times a symbol without supplemental is decoded before transmission. The range is from two to thirty times. Five or above is recommended when decoding a mix of UPC/EAN/JAN symbols with and without supplemental, and the auto discriminate option is selected. The default is set at 10. Scan the bar code below to set a decode redundancy value.
Transmit UPC-E Check Digit The check digit is the last character of the symbol used to verify the integrity of the data. Scan the appropriate bar code below to transmit the bar code data with or without the UPC-E check digit. It is always verified to guarantee the integrity of the data. < Transmit UPC-E Check Digit > Do Not Transmit UPC-E Check Digit Transmit UPC-E1 Check Digit The check digit is the last character of the symbol used to verify the integrity of the data.
UPC-A Preamble Preamble characters are part of the UPC symbol, and include Country Code and System Character. There are three options for transmitting a UPC-A preamble to the host device: transmit System Character only, transmit System Character and Country Code (“0” for USA), and transmit no preamble. Select the appropriate option to match the host system.
UPC-E Preamble Preamble characters are part of the UPC symbol, and include Country Code and System Character. There are three options for transmitting a UPC-E preamble to the host device: transmit System Character only, transmit System Character and Country Code (“0” for USA), and transmit no preamble. Select the appropriate option to match the host system.
UPC-E1 Preamble Preamble characters are part of the UPC symbol, and include Country Code and System Character. There are three options for transmitting a UPC-E1 preamble to the host device: transmit System Character only, transmit System Character and Country Code (“0” for USA), and transmit no preamble. Select the appropriate option to match the host system.
Convert UPC-E1 to UPC-A Enable this to convert UPC-E1 decoded data to UPC-A format before transmission. After conversion, the data follows UPC-A format and is affected by UPC-A programming selections (e.g., Preamble, Check Digit). When disabled, UPC-E1 decoded data is transmitted as UPC-E1 data, without conversion.
UCC Coupon Extended Code When enabled, this parameter decodes UPC-A bar codes starting with digit ‘5’, EAN-13 bar codes starting with digit ‘99’, and UPCA/EAN-128 Coupon Codes. UPCA, EAN-13, and EAN-128 must be enabled to scan all types of Coupon Codes. Enable UCC Coupon Extended Code < Disable UCC Coupon Extended Code > Note: Use the Decode UPC/EAN Supplemental Redundancy parameter to control auto discrimination of the EAN128 (right half) of a coupon code.
CODE 128 Enable/Disable Code 128 To enable or disable Code 128, scan the appropriate bar code below. < Enable Code 128 > Disable Code 128 Enable/Disable UCC/EAN-128 To enable or disable UCC/EAN-128, scan the appropriate bar code below.
Enable/Disable ISBT 128 ISBT 128 is a variant of Code 128 used in the blood bank industry. Scan a bar code below to enable or disable ISBT 128. If necessary, the host must perform concatenation of the ISBT data.
CODE 39 Enable/Disable Code 39 To enable or disable Code 39, scan the appropriate bar code below. < Enable Code 39 > Disable Code 39 Enable/Disable Trioptic Code 39 Trioptic Code 39 is a variant of Code 39 used in the marking of computer tape cartridges. Trioptic Code 39 symbols always contain six characters. To enable or disable Trioptic Code 39, scan the appropriate bar code below.
Convert Code 39 to Code 32 Code 32 is a variant of Code 39 used by the Italian pharmaceutical industry. Scan the appropriate bar code below to enable or disable converting Code 39 to Code 32. Note: Code 39 must be enabled for this parameter to function. Enable Convert Code 39 to Code 32 < Disable Convert Code 39 to Code 32 > Code 32 Prefix Scan the appropriate bar code below to enable or disable adding the prefix character “A” to all Code 32 bar codes.
Set Lengths for Code 39 The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for Code 39 to any length, one or two discrete lengths, or lengths within a specific range. If Code 39 Full ASCII is enabled, Length within a Range or Any Length is the preferred options. Note: When setting lengths for different bar code types by scanning single digit numbers, single digit numbers must always be preceded by a leading zero.
Code 39 - Length Within Range Code 39 - Any Length Code 39 Check Digit Verification When this feature is enabled, the decoder checks the integrity of all Code 39 symbols to verify that the data complies with specified check digit algorithm. Only Code 39 symbols which include a modulo 43 check digit are decoded. Enable this feature if the Code 39 symbols contain a Modulo 43 check digit.
Transmit Code 39 Check Digit Scan a bar code below to transmit Code 39 data with or without the check digit. Transmit Code 39 Check Digit (Enable) < Do Not Code 39 Check Digit > (Disable) Note: Code 39 Check Digit Verification must be enabled for this parameter to function. Code 39 Full ASCII Conversion Code 39 Full ASCII is a variant of Code 39 which pairs characters to encode the full ASCII character set. To enable or disable Code 39 Full ASCII, scan the appropriate bar code below.
Code 39 Buffering (Scan & Store) This feature allows the decoder to accumulate data from multiple Code 39 symbols. Selecting the Scan and Store option (Buffer Code 39) temporarily buffers all Code 39 symbols having a leading space as a first character for later transmission. The leading space is not buffered. Decode of a valid Code 39 symbol with no leading space causes transmission in sequence of all buffered data in a first-in first-out format, plus transmission of the “triggering” symbol.
Buffer Data To buffer data, Code 39 buffering must be enabled and a Code 39 symbol must be read with a space immediately following the start pattern. Unless the data overflows the transmission buffer, the decoder issues a lo/hi beep to indicate successful decode and buffering. (For overflow conditions, see Overfilling Transmission Buffer.) The decoder adds the decoded data excluding the leading space to the transmission buffer. No transmission occurs.
Note: The Transmit Buffer contains only a plus (+) character. In order to scan this command, be sure Code 39 length is set to include length 1. Overfilling Transmission Buffer The Code 39 buffer holds 200 characters. If the symbol just read results in an overflow of the transmission buffer: The decoder indicates that the symbol was rejected by issuing three long, high beeps. No transmission occurs. The data in the buffer is not affected.
CODE 93 Enable/Disable Code 93 To enable or disable Code 93, scan the appropriate bar code below. Enable Code 93 < Disable Code 93 > Set Lengths for Code 93 The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for Code 93 to any length, one or two discrete lengths, or lengths within a specific range. One Discrete Length - Select this option to decode only Code 93 symbols containing a selected length.
Length Within Range - Select this option to decode a Code 93 symbol with a specific length range. Select lengths using the numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode Code 93 symbols containing between 4 and 12 characters, first scan Code 93 - Length Within Range. Then scan 0, 4, 1, and 2 (single digit numbers must always be preceded by a leading zero). To correct an error or change the selection, scan Cancel barcode.
CODE 11 To enable or disable Code 11, scan the appropriate bar code below. Enable Code 11 < Disable Code 11 > Set Lengths for Code 11 The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for Code 11 to any length, one or two discrete lengths, or lengths within a specific range. One Discrete Length - Select this option to decode only Code 11 symbols containing a selected length.
Length Within Range - Select this option to decode a Code 11 symbol with a specific length range. Select lengths using numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode Code 11 symbols containing between 4 and 12 characters, first scan Code 11 - Length Within Range. Then scan 0, 4, 1, and 2 (single digit numbers must always be preceded by a leading zero). To correct an error or change the selection, scan Cancel barcode.
Code 11 Check Digit Verification This feature allows the decoder to check the integrity of all Code 11 symbols to verify that the data complies with the specified check digit algorithm. This selects the check digit mechanism for the decoded Code 11 bar code. The options are to check for one check digit, check for two check digits, or disable the feature. To enable this feature, scan the bar code below corresponding to the number of check digits encoded in the Code 11 symbols.
INTERLEAVED 2 OF 5 (ITF) Enable/Disable Interleaved 2 of 5 To enable or disable Interleaved 2 of 5, scan the appropriate bar code below, and select an Interleaved 2 of 5 length from the following pages. < Enable Interleaved 2 of 5 > Disable Interleaved 2 of 5 Set Lengths for Interleaved 2 of 5 The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
first scan I 2 of 5 - Length Within Range. Then scan 0, 4, 1, and 2 (single digit numbers must always be preceded by a leading zero). To correct an error or change the selection, scan Cancel barcode. Any Length - Scan this option to decode I 2 of 5 symbols containing any number of characters within the decoder capability.
I 2 of 5 Check Digit Verification When this feature is enabled, the decoder checks the integrity of all I 2 of 5 symbols to verify the data complies with either the specified Uniform Symbology Specification (USS), or the Optical Product Code Council (OPCC) check digit algorithm. < Disable > USS Check Digit OPCC Check Digit Transmit I 2 of 5 Check Digit Scan the appropriate bar code below to transmit I 2 of 5 data with or without the check digit.
Convert I 2 of 5 to EAN-13 Enable this parameter to convert 14-character I 2 of 5 codes to EAN-13, and transmit to the host as EAN-13. To accomplish this, the I 2 of 5 code must be enabled, and the code must have a leading zero and a valid EAN-13 check digit.
DISCRETE 2 OF 5 (DTF) Enable/Disable Discrete 2 of 5 To enable or disable Discrete 2 of 5, scan the appropriate bar code below. Enable Discrete 2 of 5 < Disable Discrete 2 of 5 > Set Lengths for Discrete 2 of 5 The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for D 2 of 5 to any length, one or two discrete lengths, or lengths within a specific range.
To correct an error or change the selection, scan Cancel barcode. Any Length - Scan this option to decode D 2 of 5 symbols containing any number of characters within the decoder capability. Note: Due to the construction of the D 2 of 5 symbology, it is possible for a scan line covering only a portion of the code to be interpreted as a complete scan, yielding less data than is encoded in the bar code.
CODABAR (NW - 7) Enable/Disable Codabar To enable or disable Codabar, scan the appropriate bar code below. Enable Codabar < Disable Codabar > Set Lengths for Codabar The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for Codabar to any length, one or two discrete lengths, or lengths within a specific range.
first scan Codabar - Length Within Range. Then scan 0, 4, 1, and 2 (single digit numbers must always be preceded by a leading zero). To correct an error or change the selection, scan Cancel barcode. Any Length - Scan this option to decode Codabar symbols containing any number of characters within the decoder capability.
CLSI Editing When enabled, this parameter strips the start and stops characters and inserts a space after the first, fifth, and tenth characters of a 14-character Codabar symbol. Enable this feature if the host system requires this data format. Note: Symbol length does not include start and stop characters. Enable CLSI Editing < Disable CLSI Editing > NOTIS Editing When enabled, this parameter strips the start and stop characters from a decoded Codabar symbol.
MSI Enable/Disable MSI To enable or disable MSI, scan the appropriate bar code below. Enable MSI < Disable MSI > Set Lengths for MSI The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for MSI to any length, one or two discrete lengths, or lengths within a specific range. One Discrete Length - Select this option to decode only MSI symbols containing a selected length.
Any Length - Scan this option to decode MSI symbols containing any number of characters within the decoder capability. Note: Due to the construction of the MSI symbology, it is possible for a scan line covering only a portion of the code to be interpreted as a complete scan, yielding less data than is encoded in the bar code. To prevent this, select specific lengths (MSI - One Discrete Length - Two Discrete Lengths) for MSI applications.
MSI Check Digits With MSI symbols, one check digit is mandatory and always verified by the reader. The second check digit is optional. If the MSI codes include two check digits, scan the Two MSI Check Digits bar code to enable verification of the second check digit. See MSI Check Digit Algorithm for the selection of second digit algorithms. < One MSI Check Digits > Two MSI Check Digits Transmit MSI Check Digit(s) Parameter # 2Eh Scan a bar code below to transmit MSI data with or without the check digit.
MSI Check Digit Algorithm Two algorithms are possible for the verification of the second MSI check digit. Select the bar code below corresponding to the algorithm used to encode the check digit.
POSTAL CODES US Postnet To enable or disable US Postnet, scan the appropriate bar code below. < Enable US Postnet > Disable US Postnet US Planet To enable or disable US Planet, scan the appropriate bar code below.
UK Postal To enable or disable UK Postal, scan the appropriate bar code below. < Enable UK Postal > Transmit UK Postal Check Digit Select whether to transmit UK Postal data with or without the check digit.
Japan Postal To enable or disable Japan Postal, scan the appropriate bar code below. Enable Japan Postal Australian Postal To enable or disable Australia Postal, scan the appropriate barcode below.
Transmit US Postal Check Digit Select whether to transmit US Postal data with or without the check digit.
GS1 DATABAR GS1 DataBar types include • GS1 DataBar Omnidirectional • GS1 DataBar Truncated • GS1 DataBar Stacked • GS1 DataBar Stacked Omnidirectional • GS1 DataBar Limited • GS1 DataBar Expanded • GS1 DataBar Expanded Stacked Scan the appropriate bar codes to enable or disable each type of GS1 DataBar.
GS1 DataBar Limited Enable GS1 DataBar Limited 118
GS1 DataBar Limited Security Level The decoder offers four levels of decode security for GS1 DataBar Limited bar codes. There is an inverse relationship between security and decoder aggressiveness. Increasing the level of security may result in reduced aggressiveness in scanning, so only choose the level of security necessary. • Level 1 – No clear margin required.
GS1 DataBar Expanded Scan the appropriate bar code below to enable or disable the following code types: • GS1 DataBar Expanded • GS1 DataBar Expanded Stacked.
Convert GS1 DataBar to UPC/EAN This parameter only applies to GS1 DataBar and GS1 DataBar Limited symbols not decoded as part of a Composite symbol. Enable this to strip the leading '010' from DataBar and DataBar Limited symbols encoding a single zero as the first digit, and report the bar code as EAN-13. For bar codes beginning with two or more zeros but not six zeros, this parameter strips the leading '0100' and reports the bar code as UPC-A.
COMPOSITE Composite CC-C Scan a bar code below to enable or disable Composite bar codes of type CC-C. Enable CC-C < Disable CC-C > Composite CC-A/B Scan a bar code below to enable or disable Composite bar codes of type CC-A/B.
Composite TLC-39 Scan a bar code below to enable or disable Composite bar codes of type TLC-39.
UPC Composite Mode UPC symbols can be “linked” with a 2D symbol during transmission as if they were one symbol. There are three options for these symbols: Select UPC Never Linked to transmit UPC bar codes regardless of whether a 2D symbol is detected. Select UPC Always Linked to transmit UPC bar codes and the 2D portion. If 2D is not present, the UPC bar code does not transmit.
Composite Beep Mode To select the number of decode beeps when a composite bar code is decoded, scan the appropriate bar code.
UCC/EAN Code 128 Emulation Mode for UCC/EAN Composite Codes Select whether to enable or disable this mode.
2D SYMBOLOGIES PDF417 Enable/Disable PDF417 To enable or disable PDF417, scan the appropriate bar code below. < Enable PDF417 > Disable PDF417 MICROPDF417 Enable/Disable MicroPDF417 To enable or disable MicroPDF417, scan the appropriate bar code below.
Code 128 Emulation When this parameter is enabled, the device transmits data from certain MicroPDF417 symbols as if it was encoded in Code 128 symbols. Transmit AIM Symbology Identifiers must be enabled for this parameter to work.
DATA MATRIX To enable or disable Data Matrix, scan the appropriate barcode below. < Enable Data Matrix > Disable Data Matrix MAXICODE To enable or disable Maxicode, scan the appropriate bar code below.
QR CODE To enable or disable QR Code, scan the appropriate bar code below. < Enable QR Code > Disable QR Code REDUNDANCY LEVEL The decoder offers four levels of decodes redundancy. Select higher redundancy levels for decreasing levels of bar code quality. As redundancy levels increase, the decoder’s aggressiveness decreases. Select the redundancy level appropriate for the bar code quality.
Redundancy Level 3 Code types other than the following must be successfully read twice before being decoded.
SECURITY LEVEL The decoder offers four levels of decode security for delta bar codes, which include the Code 128 family, UPC/EAN, and Code 93. Select increasing levels of security for decreasing levels of bar code quality. There is an inverse relationship between security and decoder aggressiveness, so choose only that level of security necessary for any given application.
INTERCHARACTER GAP SIZE The Code 39 and Codabar symbologies have an intercharacter gap that is typically quite small. Due to various bar code-printing technologies, this gap can grow larger than the maximum size allowed, preventing the decoder from decoding the symbol. If this problem occurs, scan the Large Intercharacter Gaps parameter to tolerate these out-of-specification bar codes.
MACRO PDF FEATURES Macro PDF is a special feature for concatenating multiple PDF symbols into one file. The decoder can decode symbols that are encoded with this feature, and can store more than 64 kb of decoded data stored in up to 50 Macro PDF symbols. Caution: When printing, keep each Macro PDF sequence separate, as each sequence has unique identifiers. Do not mix bar codes from several Macro PDF sequences, even if they encode the same data.
Macro PDF Transmit / Decode Mode Symbols Select one of the options below for handling Macro PDF decoding. In Buffer All Symbols the decoder can handle sets of up to 50 maximum-sized Macro PDF symbols. In all other modes there is no limit to the size of the Macro PDF set. Buffer All Symbols / Transmit Macro PDF When Complete: This transmits all decode data from an entire Macro PDF sequence only when the entire sequence is scanned and decoded.
Transmit Any Symbol in Set / No Particular Order < Pass through All Symbols > Transmit Macro PDF Control Header When enabled, this activates transmission of the control header, which contains the segment index and the file ID, in Macro PDF symbols. For example, the field may be: \92800000\725\120\343. The five digits after the \928 are the segment index (or block index), and \725\120\343 is the file ID.
Escape Characters This enables the backslash (\) character as an Escape character for systems that can process transmissions containing special data sequences. Scan a bar code below to either format special data according to the GLI (Global Label Identifier) protocol, or to disable this parameter. This parameter only affects the data portion of a Macro PDF symbol transmission; the Macro PDF Control Header (if enabled) is always sent with GLI formatting.
Chapter 8 Miscellaneous Scanner Options Introduction This chapter includes commonly used bar codes to customize how data is transmitted to the host device. See Appendix A, Standard Default Parameters for all host device and miscellaneous scanner defaults. If the default values suit requirements, programming is not necessary. There are two ways to change a parameter value: Scan the appropriate bar codes in this guide. These new values replace the standard default values in memory.
Miscellaneous Scanner Parameter Defaults Table below lists the defaults for miscellaneous scanner options parameters. To change any option, scan the appropriate barcode(s) provided in the Miscellaneous Scanner Parameter. Note: See Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters.
Miscellaneous Scanner Parameters TRANSMIT CODE ID CHARACTER A Code ID character identifies the code type of a scanned bar code. This is useful when the decoder is decoding more than one code type. In addition to any single character prefix already selected, the Code ID character is inserted between the prefix and the decoded symbol. Select no Code ID character, a Symbol Code ID character, or an AIM Code ID character. For Code ID Characters, see Symbol Code Identifiers and AIM Code Identifiers.
PREFIX/SUFFIX VALUES A prefix and/or one or two suffixes can be appended to scan data for use in data editing. To set a value for a prefix or suffix, scan a prefix or suffix bar code below, then scan a four-digit number (i.e., four barcodes from Appendix D, Numeric Bar Codes) that corresponds to that value. To correct an error or change a selection, scan Cancel barcode. Note: To use Prefix/Suffix values, first set the Scan Data Transmission Format.
SCAN DATA TRANSMISSION FORMAT To change the scan data format, scan one of the following eight bar codes corresponding to the desired format. If using this parameter do not use ADF rules to set the prefix/suffix. To set values for the prefix and/or suffix, see Prefix/Suffix Values.
FN1 SUBSTITUTION VALUES The Wedge and USB HID Keyboard hosts support a FN1 Substitution feature. When enabled any FN1 character (0x1b) in an EAN128 bar code is substituted with a value. This value defaults to 7013 (Enter Key). When using host commands to set the FN1 substitution value, set the key category parameter to 1, then set the 3-digit keystroke value. See the ASCII Character Set table for the currently installed host interface for the desired value.
TRANSMIT “NO READ” MESSAGE Scan a bar code below to select whether or not to transmit a No Read message. When enabled, the characters NR are transmitted when a bar code is not decoded. When disabled, if a symbol does not decode, nothing is sent to the host.
Chapter 9 Bluetooth Configuration This Chapter is only adaptable for EC IG-‐2DBT. SCANNER MODE SELECTION < SPP Master Mode > Please follow the steps to setup the communication between the scanner and cradle. 1) The scanner must scan “SPP Master Mode” barcode to set the scanner in master mode. 2) Scan the Bluetooth MAC address code located on the bottom of the cradle.
HID Slave Mode To setup the communication between the scanner and Bluetooth HID profile application device, follow the steps. 1) The scanner must scan “HID Slave Mode” barcode to set the scanner in HID slave mode. 2) When control the Bluetooth device to search the scanner, enter pin code to setup pairing. You can scan number barcode on Appendix A, “Decimal Value Table ” number 0~9, to setup. 3) When scanner is successful connected, scanner blue LED will also blink with up-tone.
OUT OF RANGE When “Out of Range” function is enabled, and the scanner is working at out of transmission range, the scanned data will be stored to out-of-range memory. Memory size is approximately 30,000 sets of EAN13 barcode type. The all stored data will be transmitted to device when the link is reconnected, and the all data stored in out-of-range memory will be cleared.
BATCH MODE “***” means “Quick Setting Label”. The function can be executed directly by scanning barcode instead of doing the general programming process.
FIRMWARE VERSION : Display the firmware version of the scanner, please scan below barcode.
APPENDIX A : STANDARD DEFAULT PARAMETERS Default Parameters Table A-1. Standard Default Parameters Table Parameter Default User Preferences Set Default Parameter All Defaults Parameter Scanning Enable Beeper Tone Medium Beeper Volume High Trigger Modes Power Mode Handheld/hands-free scanner Level Scan module Presentation Handheld/hands-free scanner Low Power Scan module Continuous On Time Delay to Low Power Mode 1.0 Sec Decode Session Timeout 9.
Decode Aiming Pattern Enable Image Capture Auto exposure Enable Image Capture Illumination Enable Gain 100 Exposure Time 10 ms LED Illumination Internal LED Illumination Snapshot Mode Timeout 0 (30 seconds) Snapshot Aiming Pattern Enable Image Cropping Disable Crop to Pixel Addresses 0 top, 0 left, 479 bottom, 639 right Image Resolution Full JPEG Image Options Quality JPEG Quality Value 65 JPEG Size Value 40 (41K) Image File Format Selection JPEG Bits per Pixel (BPP) 8 BPP Si
Target Video Frame Size 2200 bytes Video View Finder Image Size 1700 bytes Event Reporting Decode Event Disable Boot Up Event Disable Parameter Event Disable Serial Host Parameters Serial Host Types SSI Host Baud Rate 9600 Parity Type None Stop Bit Select 1 Stop Bit Data Bits 8-Bit Check Receive Errors Enable Hardware Handshaking None Software Handshaking None Host Serial Response Time-out 2 Sec RTS Line State Low RTS Beep on Disable Intercharacter Delay 0 msec Nixdor
Symbol Native API (SNAPI) Status Handshaking Enable USB Country Keyboard Types (Country Codes) North American USB Keystroke Delay No Delay USB CAPS Lock Override Disable USB Ignore Unknown Characters Enable Emulate Keypad Disable USB FN1 Substitution Disable Function Key Mapping Disable Simulated Caps Lock Disable Convert Case None UPC/EAN UPC-A Enable UPC-E Enable UPC-E1 Disable EAN-8/JAN 8 Enable EAN-13/JAN 13 Enable Bookland EAN Disable Decode UPC/EAN/JAN Supplemental (2 a
System Character System Character UPC-E Preamble UPC-E1 Preamble Convert UPC-E to A Disable Convert UPC-E1 to A Disable EAN-8/JAN-8 Extend Disable UCC Coupon Extended Code Disable Code 128 Code 128 Enable UCC/EAN-128 Enable ISBT 128 Enable Code 39 Code 39 Enable Trioptic Code 39 Disable Convert Code 39 to Code 32 (Italian Pharmacy Code) Disable Code 32 Prefix Disable Set Length(s) for Code 39 2 to 55 Code 39 Check Digit Verification Disable Transmit Code 39 Check Digit Disable C
Code 11 Code 11 Disable Set Lengths for Code 11 4 to 55 Code 11 Check Digit Verification Disable Transmit Code 11 Check Digit(s) Disable Interleaved 2 of 5 (ITF) Interleaved 2 of 5 (ITF) Enable Set Lengths for I 2 of 5 14 I 2 of 5 Check Digit Verification Disable Transmit I 2 of 5 Check Digit Disable Convert I 2 of 5 to EAN 13 Disable Discrete 2 of 5 (DTF) Discrete 2 of 5 Disable Set Length(s) for D 2 of 5 12 Codabar (NW - 7) Codabar Disable Set Lengths for Codabar 5 to 55 CLSI Edi
Transmit MSI Check Digit Disable MSI Check Digit Algorithm Mod 10/Mod 10 Postal Codes US Postnet Enable US Planet Enable UK Postal Enable Transmit UK Postal Check Digit Enable Japan Postal Enable Australian Postal Enable Dutch Postal Enable Transmit US Postal Check Digit Enable RSS (Reduced Space Symbology) RSS 14 Enable RSS Limited Enable RSS Expanded Enable Convert RSS to UPC/EAN Disable Composite Composite CC-C Disable Composite CC-A/B Disable Composite TLC-39 Disable UP
UCC/EAN Code 128 Emulation Mode for UCC/EAN Composite Codes Disable 2D Symbologies PDF417 Enable MicroPDF417 Disable Code 128 Emulation Disable Data Matrix Enable Maxicode Enable QR Code Enable Symbology-Specific Security Levels Redundancy Level 1 Security Level 1 Intercharacter Gap Size Normal Report Version Macro PDF Macro PDF Transmit/Decode Mode Symbols Pass through Mode Transmit Macro PDF Control Header Disable Escape Characters None Flush Macro PDF Buffer Page 134 Abort Mac
SSI Suffix 1 Value SSI Suffix 2 Value Non-SSI Prefix Value Non-SSI Suffix 1 Value Non-SSI Suffix 2 Value Scan Data Transmission Format Data as is FN1 Substitution Values Set Transmit “No Read” Message Disable 158
APPENDIX B : SYMBOL CODE IDENTIFIERS Symbol Code Characters Code Character Code Type A UPC-A, UPC-E, UPC-E1, EAN-8, EAN-13 B Code 39, Code 32 C Codabar D Code 128 E Code 93 F Interleaved 2 of 5 G Discrete 2 of 5, or Discrete 2 of 5 IATA H Code 11 J MSI K UCC/EAN-128 L Bookland EAN M Trioptic Code 39 N Coupon Code R RSS Family T UCC Composite, TLC 39 X PDF417, Macro PDF417, Micro PDF417 P00 Data Matrix P01 QR Code P02 Maxicode 159
P03 US Postnet P04 US Planet P05 Japan Postal P06 UK Postal P08 Dutch Postal P09 Australian Postal P09 UK Postal 160
AIM Code Identifiers Each AIM Code Identifier contains the three-character string ]cm where: ] = Flag Character (ASCII 93) c = Code Character m = Modifier Character Aim Code Characters Code Character Code Type A Code 39, Code 39 Full ASCII, Code 32 C Code 128, Coupon (Code 128 portion) d Data Matrix E UPC/EAN, Coupon (UPC portion) e RSS Family F Codabar G Code 93 H Code 11 I Interleaved 2 of 5 L PDF417, Macro PDF417, Micro PDF417 M MSI Q QR Code S Discrete 2 of 5, IATA 2 of 5 U
The modifier character is the sum of the applicable option values based on Table B-3. Modifier Characters Option Code Type Option Value 0 No check character or Full ASCII processing. 1 Code 39 Trioptic Code 39 Code 128 I 2 of 5 Reader has checked one check character. Reader has checked and stripped check 3 character. Reader has performed Full ASCII character 4 conversion. Reader has performed Full ASCII character 5 conversion and checked one check character.
transmitted as ]F04123 No options specified at this time. Always transmit 0. Example: A Code 93 bar code 012345678905 is transmitted as ]G0012345678905 0 Check digits are sent. 0 Code 93 MSI D 2 of 5 UPC/EAN 1 No check digit is sent. Example: An MSI bar code 4123, with a single check digit checked, is transmitted as ]M14123 No options specified at this time. Always transmit 0 0.
EAN.UCC Composites (RSS, UCC/EAN-128, 2D portion of UPC composite) 1 2 3 Data packet containing the data following an encoded symbol separator character. Data packet containing the data following an escape mechanism character. The data packet does not support the ECI protocol. Data packet containing the data following an escape mechanism character. The data packet supports the ECI protocol. UCC/EAN-128 emulation Note: UPC portion of composite is transmitted using UPC rules.
4 0 ECC 200, FNC1 in first or fifth position, ECI protocol implemented. ECC 200, FNC1 in second or sixth position, ECI protocol implemented. Symbol in Mode 4 or 5. 1 Symbol in Mode 2 or 3. 5 6 MaxiCode 2 3 QR Code ECC 200, ECI protocol implemented. Symbol in Mode 4 or 5, ECI protocol implemented. Symbol in Mode 2 or 3, ECI protocol implemented in secondary message. 0 Model 1 symbol. 1 Model 2 symbol, ECI protocol not implemented. 2 Model 2 symbol, ECI protocol implemented.
APPENDIX C : ASCII Character Set ASCII Value Table ASCII Value Full ASCII Code 39 Encode Char Keystroke 1000 %U CTRL 2 1001 $A CTRL A 1002 $B CTRL B 1003 $C CTRL C 1004 $D CTRL D 1005 $E CTRL E 1006 $F CTRL F 1007 $G CTRL G 1008 $H 1009 $I 1010 $J CTRL J 1011 $K CTRL K 1012 $L CTRL L 1013 $M CTRL M/ENTER 1014 $N CTRL N 1015 $O CTRL O 1016 $P CTRL P 1017 $Q CTRL Q CTRL 1 H/BACKSPACE CTRL I/HORIZONTAL 1 TAB 166 1
1018 $R CTRL R 1019 $S CTRL S 1020 $T CTRL T 1021 $U CTRL U 1022 $V CTRL V 1023 $W CTRL W 1024 $X CTRL X 1025 $Y CTRL Y 1026 $Z CTRL Z 1027 %A CTRL [ 1028 %B CTRL \ 1029 %C CTRL ] 1030 %D CTRL 6 1031 %E CTRL 1032 Space Space 1033 /A ! 1034 /B “ 1035 /C # 1036 /D $ 1037 /E % 1038 /F & 1039 /G ‘ 1040 /H ( 167
1041 /I ) 1042 /J * 1043 /K + 1044 /L , 1045 - - 1046 . .
1064 %V @ 1065 A A 1066 B B 1067 C C 1068 D D 1069 E E 1070 F F 1071 G G 1072 H H 1073 I I 1074 J J 1075 K K 1076 L L 1077 M M 1078 N N 1079 O O 1080 P P 1081 Q Q 1082 R R 1083 S S 1084 T T 1085 U U 1086 V V 169
1087 W W 1088 X X 1089 Y Y 1090 Z Z 1091 %K [ 1092 %L \ 1093 %M ] 1094 %N ^ 1095 %O _ 1096 %W ‘ 1097 +A a 1098 +B b 1099 +C c 1100 +D d 11 +E e 11 +F f 11 +G g 11 +H h 11 +I i 1106 +J j 1107 +K k 1108 +L l 1109 +M m 170
1110 +N n 1111 +O o 1112 +P p 1113 +Q q 1114 +R r 1115 +S s 1116 +T t 1117 +U u 1118 +V v 1119 +W w 1120 +X x 1121 +Y y 1122 +Z z 1123 %P { 1124 %Q I 1125 %R } 1126 %S ~ The keystroke in bold is sent only if the Function Key Mapping is enabled. Otherwise, the unbold keystroke is sent.
ALT Key Standard Default Tables ALT Keys Keystroke 2064 ALT 2 2065 ALT A 2066 ALT B 2067 ALT C 2068 ALT D 2069 ALT E 2070 ALT F 2071 ALT G 2072 ALT H 2073 ALT I 2074 ALT J 2075 ALT K 2076 ALT L 2077 ALT M 2078 ALT N 2079 ALT O 2080 ALT P 2081 ALT Q 2082 ALT R 2083 ALT S 2084 ALT T 2085 ALT U 2086 ALT V 2087 ALT W 2088 ALT X 2089 ALT Y 2090 ALT Z 172
USB GUI Key Character Set GUI Key Keystroke 3000 Right Control Key 3048 GUI 0 3049 GUI 1 3050 GUI 2 3051 GUI 3 3052 GUI 4 3053 GUI 5 3054 GUI 6 3055 GUI 7 3056 GUI 8 3057 GUI 9 3065 GUI A 3066 GUI B 3067 GUI C 3068 GUI D 3069 GUI E 3070 GUI F 3071 GUI G 3072 GUI H 3073 GUI I 3074 GUI J 3075 GUI K 3076 GUI L 3077 GUI M 3078 GUI N 3079 GUI O 3080 GUI P 173
3081 GUI Q 3082 GUI R 3083 GUI S 3084 GUI T 3085 GUI U 3086 GUI V 3087 GUI W 3088 GUI X 3089 GUI Y 3090 GUI Z Note: GUI Shift Keys - The Apple™ iMac keyboard has an apple key on either side of the space bar. Windows-based systems have a GUI key to the left of the left ALT key, and to the right of the right ALT key.
PF Key Standard Default Table PF Keys Keystroke 40 PF 1 40 PF 2 40 PF 3 40 PF 4 40 PF 5 40 PF 6 40 PF 7 40 PF 8 40 PF 9 40 PF 10 40 PF 11 40 PF 12 40 PF 13 40 PF 14 40 PF 15 40 PF 16 175
F key Standard Default Table F Keys Keystroke 5001 F1 5002 F2 5003 F3 5004 F4 5005 F5 5006 F6 5007 F7 5008 F8 5009 F9 5010 F 10 5011 F 11 5012 F 12 5013 F 13 5014 F 14 5015 F 15 5016 F 16 5017 F 17 5018 F 18 5019 F 19 5020 F 20 5021 F 21 5022 F 22 5023 F 23 5024 F 24 176
Numeric Key Standard Default Table Numeric Keypad Keystroke 6042 * 6043 + 6044 Undefined 6045 - 6046 .
Extended Keypad Standard Default Table Extended Keypad Keystroke 7001 Break 7002 Delete 7003 Pg Up 7004 End 7005 Pg Dn 7006 Pause 7007 Scroll Lock 7008 Backspace 7009 Tab 7010 Print Screen 7011 Insert 7012 Home 7013 Enter 7014 Escape 7015 Up Arrow 7016 Dn Arrow 7017 Left Arrow 7018 Right Arrow 178
APPENDIX D : Numeric Bar Codes For parameters requiring specific numeric values, scan the appropriately numbered bar code(s).
8 9 Cancel To correct an error or change a selection, scan the bar code below.
APPENDIX E : Readable Symbologies 1D Symbologies Default Enable Symbologies EAN/UPC UPC-A UPC-E UPC-E1 EAN-8/JAN 8 EAN-13/JAN 13 Bookland EAN Bookland ISBN Format Decode UPC/EAN/JAN Supplementals (2 and 5 digits) UPC/EAN/JAN Supplemental Redundancy Decode UPC/EAN/JAN Supplemental AIM ID Transmit UPC-A Check Digit Transmit UPC-E Check Digit Transmit UPC-E1 Check Digit UPC-A Preamble UPC-E Preamble UPC-E1 Preamble Convert UPC-E to A Convert UPC-E1 to A EAN-8/JAN-8 Extend UCC Coupon Extended Code Coupon Repo
Default Enable Symbologies Code 128 Code 128 Set Length(s) for Code 128 GS1-128 (formerly UCC/EAN-128) ISBT 128 ISBT Concatenation Check ISBT Table ISBT Concatenation Redundancy ○ Any Length ○ ○ Disable ○ 10 Code 39 Code 39 ○ Trioptic Code 39 Convert Code 39 to Code 32 (Italian Pharmacy Code) Code 32 Prefix Set Length(s) for Code 39 Code 39 Check Digit Verification Transmit Code 39 Check Digit Code 39 Full ASCII Conversion Buffer Code 39 Code 93 Code 93 Set Length(s) for Code 93 Code 11 Code 11 Set Len
Interleaved 2 of 5 (ITF) Interleaved 2 of 5 (ITF) Disable 1 Length; Set Lengths for I 2 of 5 Length = 14 I 2 of 5 Check Digit Verification Transmit I 2 of 5 Check Digit Convert I 2 of 5 to EAN 13 Discrete 2 of 5 (DTF) Discrete 2 of 5 Set Length(s) for D 2 of 5 Disable Disable Disable Disable 1 Length; Length = 12 Codabar (NW - 7) Codabar Set Lengths for Codabar CLSI Editing NOTIS Editing Codabar Upper or Lower Case Start/Stop Characters Detection MSI MSI Set Length(s) for MSI MSI Check Digits Transmit MSI
Korean 3 of 5 Korean 3 of 5 Inverse 1D Disable Regular Postal Codes US Postnet US Planet Transmit US Postal Check Digit UK Postal Disable Disable ○ Disable Transmit UK Postal Check Digit Japan Postal ○ Disable Disable Autodiscriminate Disable Australia Post Australia Post Format Netherlands KIX Code USPS 4CB/One Code/Intelligent Mail Disable Disable UPU FICS Postal GS1 DataBar GS1 DataBar (GS1 DataBar Omnidirectional, GS1 DataBar Truncated, GS1 DataBar Stacked, GS1 DataBar Stacked Omnidirection
Composite Composite CC-C Composite CC-A/B Disable Disable Disable UPC Always Linked Beep As Each Code Type is Decoded Composite TLC-39 UPC Composite Mode Composite Beep Mode GS1-128 Emulation Mode for UCC/EAN Composite Codes Disable 2D Symbologies Default Enable ○ Disable Disable ○ Regular Symbologies PDF417 MicroPDF417 Code 128 Emulation Data Matrix Data Matrix Inverse Decode Mirror Images (Data Matrix Only) Auto Maxicode QR Code QR Inverse MicroQR Aztec Aztec Inverse Redundancy Level Security Leve