User Manual

Chengdu Ebyte Electronic Technology Co.,Ltd E22-230TXXS User Manual
Copyright ©2012–2022Chengdu Ebyte Electronic Technology Co.,Ltd 4
03H
Read/Wr
ite
REG0
765 UART: Serial port ratebps
000: 1200
001: 2400
010: 4800
011: 9600default
100: 19200
101: 38400
110: 57600
111: 115200
---------------------------------------
4
3
Serial parity bit
008N1default
018O1
108E1
118N1equal to 00
-----------------------------------
2
1
0
air data rate
000: 0.3k
001: 1.2k
010: 2.4k
default
011: 4.8k
100: 9.6k
101: 19.2k
110: 38.4k
111: 62.5k
For the two modules that communicate with each
other, the serial port baud rate can be different, and
the verification method can also be different.
When transmitting large packets continuously, users
need to consider the data blocking caused by the same
baud rate, and data may even be lost. It is generally
recommended that both parties have the same baud
rate.
---------------------------------------
Both parties must be the same
The higher the rate, the shorter the distance
04H
Read/Wr
ite
REG1
76 Sub packet setting
00: 240 bytes
default
01: 128 bytes
10: 64 bytes
11: 32 bytes
--------------------------------------
5
RSSI Ambient noise enable
1: Enable
0: Disable
default
--------------------------------------
432 Reserve
--------------------------------------
10 Transmitting power
00
22dbm
default
01
17dbm
1013dbm
1110dbm
When the data is smaller than the sub packet length,
the serial output of the receiving end is an
uninterrupted continuous output.
When the data is larger than the sub packet length,
the receiving end serial port will output the sub
packet.
--------------------------------------------
When enabled, the C0 C1 C2 C3 command can be
sent in the transmitting mode or WOR transmitting
mode to read the register.
Register 0x00: Current ambient noise rssi
Register 0X01: rssi when the data was received last
time.
Current channel noise is: dBm =-RSSI/2
Command format: C0 C1 C2 C3 + starting address +
read length
Returns: C1 + address address + read length + read valid
value
E.g: send C0 C1 C2 C3 00 01
Return C1 00 01 rssi
-----------------------------------------------
Power and current are nonlinear, and power
efficiency is highest at maximum power.
The current does not decrease in proportion to the
decrease in power.