User Manual

Chengdu Ebyte Electronic Technology Co., Ltd. E180-ZG120A/B Product Specification
Copyright ©2012–2020Chengdu Ebyte Electronic Technology Co., Ltd.
to extend the antenna to the outside of the casing;
The antenna must not be installed inside the metal shell, which will greatly weaken the transmission distance.
5.4 software writing
The core of this module is EFR32, and its driving method is completely equivalent to EFR32. Users can operate according to the
EFR32 chip manual (see EFR32 manual for details);
Burning program: The module is a SOC module with its own GPIO port, and the program download uses the J-LINK dedicated
downloader.
Note: After the second burning, the original firmware will not be available!
Program download interface definition
pin
J-LINK interface
VCC
VCC
PF0
SWCLK
PF1
SWDIO
GND
GND
6. Common problem
6.1 The transmission distance is not ideal
When there is a straight-line communication obstacle, the communication distance will be correspondingly attenuated;
Temperature, humidity, and co-channel interference will increase the communication packet loss rate;
The ground absorbs and reflects radio waves, and the test effect close to the ground is poor;
Seawater has a strong ability to absorb radio waves, so the seaside test effect is poor;
If there is a metal object near the antenna, or placed in a metal shell, the signal attenuation will be very serious;
The power register is set incorrectly, and the air rate is set too high (the higher the air rate, the closer the distance);
The low voltage of the power supply at room temperature is lower than the recommended value, and the lower the voltage, the
lower the output power;
Poor matching between the antenna and the module or the quality of the antenna itself.
6.2 Module is easily damaged
Please check the power supply to ensure that it is between the recommended supply voltages, if exceeding the maximum value
will cause permanent damage to the module;
Please check the stability of the power supply, the voltage should not fluctuate greatly and frequently;
Please ensure anti-static operation during installation and use, and high-frequency components are electrostatically sensitive;
Please ensure that the humidity during installation and use should not be too high, and some components are humidity-sensitive
devices;
If there is no special requirement, it is not recommended to use it at too high or too low temperature.