User Manual

Chengdu Ebyte Electronic Technology Co., Ltd. E108-D01 User Manual
Copyright ©2012–2022, Chengdu Ebyte Electronic Technology Co., Ltd.
15
5.3.2 Modify baud rate
Command frame: 01 06 00 03 00 03 39 CB
Address
Function code
Register start address
Number of
registers
CRC check
0x01
0x06
0x00 0x03
0x00 0x03
0x39 0xCB
Response frame: 01 06 00 03 00 03 39 CB
Address
Function code
Register start address
Number of
registers
CRC check
0x01
0x06
0x00 0x03
0x00 0x03
0x39 0xCB
Note:
This command is used to set the baud rate of the device to 9600.
The device defaults to 9600 baud rate without verification when it leaves the factory. Users can set the baud rate and
verification method according to actual needs.
5.5.3 Modify the parity
Command frame: 01 06 00 06 00 04 09 CB
Address
Function code
Register start address
Number of
registers
CRC check
0x01
0x06
0x00 0x06
0x00 0x04
0x09 0xCB
Response frame: 01 06 00 06 00 04 09 CB
Address
Function code
Register start address
Number of
registers
CRC check
0x01
0x06
0x00 0x06
0x00 0x04
0x09 0xCB
Note:
This command is used to set the parity bit of the device to odd parity.
The final interpretation right belongs to Chengdu Ebyte Electronic Technology Co., Ltd.
Revise history
Version
Revise date
Revise instruction
Issued by
1.0
2022-05-05
Initial version
LC
1.1
2022-05-31
Content revision
XXN