6.4.58 AT+FILTER Device master filtering conditions
command respond
Set AT+FILTER =[type], [sta]
+OK:Success
+ERR=[NUM]:Error
Parameter
[type]
Type
description
1
Filter according to name
[sta]
Sta
description
0 Turn off filtering
1
Turn on filtering
Remarks
1. Take into effect immediately, do not save once power off
2. Only valid for firmware:V1.1
For example
The master filter with name “E104-BT50”.
1. Set the filter name (default name: E104-BT5032A), and instruct AT + NAME = E104-BT50 or AT +
NAME1 = E104-BT50.
2. Turn on name filtering. Command AT + FILTER = 1,1;
As a result, the master only contains "E104-BT50" in front of the name, such as "E104-BT5032A",
"E104-BT5010A", and so on.