6.4.47 AT+PWR transmitting power
command respond
Query AT+ PWR? +OK=[para]
Set AT+ PWR =[para]
+OKsuccess
+ERR=[NUM]error
Parameter
para(ASCII) val
0 4 dBm
1 3 dBm
2
0 dBmdefault
3 -4 dBm
4 -8 dBm
5 -12 dBm
6 -16 dBm
7 -20 dBm
8 -40 dBm
Remarks Take into effect immediately, save after power off
6.4.48 AT+ONSLEEP sleep once power on
command respond
Query AT+ONSLEEP? +OK=[para]
Set AT+ONSLEEP =[para]
+OKsuccess
+ERR=[NUM]error
Parameter
paraASCII
Description
0 Disenable(default)
1 Enable
Remarks Take into effect immediately, save after power off
6.4.49 AT+DISCSLEEP disconnect and get into sleep
command respond
Query AT+DISCSLEEP? +OK=[para]
Set AT+DISCSLEEP =[para]
+OKsuccess
+ERR=[NUM]error