User's Manual

Chengdu Ebyte Electronic Technology Co., Ltd E104-BT5032A User Manual
Copyright ©2012–2019Chengdu Ebyte Electronic Technology Co., Ltd
35
6.4.37 AT+TRANMD master transmission mode
command respond
Query AT+TRANMD? +OK=[para]
Set AT+ TRANMD =[ para]
+OKsuccess
+ERR=[NUM]error
Parameter
paraASCII
Description
0
Non-transparent transmissiondefault
1 Transparent transmission
Remarks
1 Take into effect immediately, save when power off
6.4.38 AT+LINKMAX Master max link quantity
command respond
Query
AT+
LINKMAST?
+OK=[para]
Set
AT+
LINKMAST =[para]
+OKsuccess
+ERR=[NUM]error
Parameter
para(ASCCII):max link quantity. range1~4
default4
Remarks
1. Take effect immediately, save after power off.
2. If 4 devices are currently connected, but 2 are set at this time, the master will not
disconnect the connected devices.
3. The instruction supports firmware version: V1.1.
4. The number of connections is limited to automatic connections only.
6.4.39 AT+LINKSLAVESlave max link quantity
command respond
Query
AT+LINKSLAVE? +OK=[para]
Set
AT+ LINKSLAVE =[para]
+OKsuccess
+ERR=[NUM]error
Parameter
para(ASCCII):max link quantity. range1~4
Dafault4
Remarks
1. Take effect immediately, save after power off.
2. If 4 devices are currently connected, but 2 are set at this time, the slave will not disconnect the connected
devices.