User's Manual
Chengdu Ebyte Electronic Technology Co., Ltd E104-BT5032A User Manual
Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd
33
Set AT+BONDDEL=[mac]
+OK
+ERR=[NUM]
Parameter
mac:6bytes mac address
Remarks
1、Take into effect immediately, save when power off
2、 When MAC is (0xff,0xff,0xff,0xff,0xff,0xff)delete all MAC address,or delate specified mac address;
6.4.31 AT+SCAN advertising scan
command respond
Query AT+SCAN? +OK=[para]
Set AT+SCAN=[para]
+OK:success
+ERR=[NUM]:error
Parameter
para(ASCII)
Description
0 Scan closed
1 Scan enabled(default)
Remarks
1、 Take into effect immediately, save when power off
2、 If current connected masters are the maximum, no scanning will be enabled
3、 Scanning is only available for master and observer
6.4.32 AT+SCANINTV scan interval
command Respond
Query AT+SCANINTV? +OK=[para]
Set AT+SCANINTV=[para]
+OK:success
+ERR=[NUM]:error
Parameter
para(ASCII):4~65535
Default: 160
Remarks
1、Take into effect immediately, save when power off
2、Scanning interval is more than scanning window
3、Unavailable for slave, but configuration is ok
For example
AT+SCANINTV=120
Interval:120*0.625 = 75ms
6.4.33 AT+SCANWND scan window
command respond
Query AT+SCANWND? +OK=[para]
Set AT+SCANWND=[para]
+OK:success
+ERR=[NUM]:error